Zone (3Rd Party) - Vaillant UK aroTHERM plus Schematics And Installation Manual

Advertisement

aroTHERM plus with DHW Cylinder, Decoupler, 1 Radiator Zone, 1 Underfloor Heating

Zone (3rd Party)

Setting
Installation
Adaptive heat. curve Deactivated
Hybrid manager Bivalence pt.
Heating bivalence point -20
DHW bivalence point: -20
Alternative point Off
ESCO Heating off
Back-up boiler Off
Conf. ext. input Open, deactiv.
Basic system diagram configuration
Basic system diagram code 10
FM3 configuration: 3
FM3 MO Not working
HP control module configuration
MO 2 Circ. pump
Circuit 1
Circuit type Heating
OT switch-off threshold 30
Heat curve **Site specific
Min. target flow temp. 15
Max. target flow temp. 45
Set-back mode Normal
Room temp. mod. Expanded
Circuit 2
Circuit type Heating
OT switch-off threshold 30
Heat curve **Site specific
Min. target flow temp. 15
Max. target flow temp. 45
Set-back mode Eco
Room temp. mod. Inactive
Zone 1
Zone activated Yes
Zone assignment Control
Zone 2
Zone activated Yes
Zone assignment No assignmt
Domestic hot water
Cylinder Active
Anti-legio. day **User pref.
Anti-legio. time **User pref.
Cylinder charging offset 15 K
Cyl. charg. anti-cycl. time 5 min
Value
o
o
o
o
o
o
o
o
17