Panasonic YC-400TX4 Operating Instructions Manual page 15

Digital igbt controlled dctig arc welding power source
Table of Contents

Advertisement

P10
Pass word
P11
Network setting
Arc start current
P12
correction
Arc start time
P13
correction
Special
P14
Frequency
setting
Low non-load
P18
output
Up & down
P22
slope(%) of spot
welding
Loop resistance
P23
test
 Factory Settings are as follows:
Power switch OFF/DC TIG/CRATER OFF/WELD/HF/GAS CHECK OFF
range: 0-9
Please contact with the sales agent if required.
0:Forbid
--to set the Menu P11 be as 0.
1: Allow
--to set the Menu P11 be as 1.
-50-+50A
Menu P12 sets the value to be the upper and lower range
adjustment of the arc start current under the state of the set
arc start current level. The range is -50A to +50A
Remarks: the correction will no work once the arc start
current reached to the lower limitation.
-30-+30ms
--
Menu P12 sets the value tobe
Arc start time correction,
the correction range is -30-+30ms
0: N/A
--to set the Menu P14 be as 0.
1:Available
--to set the Menu P14 be as 1. The output frequency is
2KHZ. At this time, enter the Pulse frequency setting states,
the right side display meter will show SPF, the PULSE FREQ
& PULSE WIDTH are not adjustable.
0:non-load output
--to set the Menu P18 be as 0. There will be non-load output
under the STICK mode.
1:safety low voltage output
--to set the Menu P18 be as 1. There will be safety low
voltage output under the STICK mode.
range: 0-50
--Menu P22 sets the value to be the Up & down slope(%).
This value is adjustable. When the value is 0, the output is
square wave; When the value is 50, the output is triangular
wave.
0: normal state
--to set the Menu P23 be as 0.
1:Loop resistance test
--to set the Menu P23 be as 1, set the MODE as WELD,
ensure the tip closely contacts with the base metal, press the
torch switch, the display meter will show the resistance value
(unit: Ω). The right side display meter shows the integer, the
left side display meter shows the digits. This function is
normally selected when the extension cable was used. After
the test, power on the machine for use.
9
Default:
123456
Default:1
Default:0
Default:0
Default:0
Default:0
Default:5
Default:0