The specific cable connection way please refer to the related battery operation manual.
Connect power cable first:
1) each pair of cable hold max 100A constant current. Connect enough pairs of cable based on
calculation of system current.
2) Suitable protection breaker between battery system and inverter is required.
3) connect power cable of LV-HUB
4) Make sure all dipswitch is X0XX, then turn ON batteries.
5) After all batteries running and buzzer of master battery in group1 rings 3 times. Means all groups are
online.
6) Change the dip switch of master battery in group1 to X1XX. Then connect communication cable
between LV-HUB and master battery in group 1.
7) Then turn ON LV-HUB.