Minelab X-TERRA PRO Instruction Manual page 43

Hide thumbs Also See for X-TERRA PRO:
Table of Contents

Advertisement

Error Codes
Some detector faults will display an Error Code on the
Target ID Number field� Try the recommended actions listed
before contacting an Authorised Service Centre�
COIL DISCONNECT ERROR
'Cd' is displayed in the event
of a Coil Disconnect Error�
In the event of a Coil Disconnect Error, follow these steps:
1. Check that the coil connector is connected properly at
the back of the Control Pod�
2. Check the coil cable for damage�
3. Check the coil for visible signs of damage�
4. Try another coil, if you have one available�
SYSTEM ERROR
System error code 'Er' will be accompanied by an error
code number shown on the Frequency Display� The detector
will shut down 5 seconds after reporting a system error�
'Er' is displayed in the event
of a System Error�
In the event of a System Error, follow these steps:
1. Restart the detector to determine if the error
still remains�
2. Confirm the coil is attached correctly�
3. Perform a Factory Reset by powering Off the detector,
then press‑and‑hold the Power button until 'FP' appears
on the Target ID Display, then release the button�
4. If the error still remains, return the detector to your
nearest Authorised Service Centre for repair�
CRITICALLY LOW BATTERY ERROR
When the battery level is critically low, 'bF' will appear
on the Target ID Display� The detector will shut down 5
seconds after reporting a Critically Low Battery Error�
'bF' is displayed in the event of
a Critically Low Battery Error�
In the event of a Critically Low Battery Error, follow
these steps:
1. Recharge the battery or connect a USB power bank�
2. Contact an Authorised Service Centre to replace the
internal battery�
CONTENTS
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents