atecpool SIROCCO AVHP265 User Manual

atecpool SIROCCO AVHP265 User Manual

Full dc inverter swimming pool heat pump

Advertisement

Quick Links

ATECPOOL SIROCCO HEAT PUMP > User Manual
SIROCCO
INVERTER HEAT PUMP
Models: AVHP265 & AVHP308 & AVHP352& AVHP411
FULL DC INVERTER SWIMMING POOL HEAT PUMP
USER MANUAL
Please read this manual carefully before using and keep it in a safe place.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIROCCO AVHP265 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for atecpool SIROCCO AVHP265

  • Page 1 ATECPOOL SIROCCO HEAT PUMP > User Manual SIROCCO INVERTER HEAT PUMP Models: AVHP265 & AVHP308 & AVHP352& AVHP411 FULL DC INVERTER SWIMMING POOL HEAT PUMP USER MANUAL Please read this manual carefully before using and keep it in a safe place.
  • Page 2 ATECPOOL SIROCCO HEAT PUMP > User Manual...
  • Page 3: Table Of Contents

    ATECPOOL SIROCCO HEAT PUMP > User Manual Contents I. Unit Parameters ........................1 1. Appearance ........................1 II. System Specification ......................2 1. Specification ........................2 2. Unit Dimensions ......................4 3. Exploded View ........................ 5 III. Installation Instructions ..................... 6 1.
  • Page 4 ATECPOOL SIROCCO HEAT PUMP > User Manual...
  • Page 5: Unit Parameters

    ATECPOOL SIROCCO HEAT PUMP > User Manual Unit Parameters Appearance Please read the below instructions. ● Please install the unit in compliance with local laws, regulations and standards; ● Confirm power voltage and frequency; ● The unit should be installed by a professional installer ⚠...
  • Page 6: System Specification

    ATECPOOL SIROCCO HEAT PUMP > User Manual System Specification 1. Specification Model AVHP265 AVHP308 Air Temperature: 27℃, inlet/outlet water temperature: 26℃/28℃, humidity 80% Heating capacity (kW) 9.2-26.5 10.3-30.8 Power input (kW) 0.62-4.34 0.7-5.06 14.82-6.1 14.7-6.09 Air Temperature: 15℃, inlet/outlet water temperature: 26℃,humidity 70% Heating capacity (kW) 7.86-17.87...
  • Page 7 ATECPOOL SIROCCO HEAT PUMP > User Manual Model AVHP352 AVHP411 Air Temperature: 27℃, inlet/outlet water temperature: 26℃/28℃, humidity 80% Heating capacity (kW) 11.7-35.2 12.9-41.1 Power input (kW) 0.79-5.77 0.88-6.95 14.82-6.1 14.74-5.91 Air Temperature: 15℃, inlet/outlet water temperature: 26℃/28℃,humidity 70% Heating capacity (kW) 8.96-24.56...
  • Page 8: Unit Dimensions

    ATECPOOL SIROCCO HEAT PUMP > User Manual 2. Unit Dimensions Model AVHP265 AVHP308 AVHP352 1054 AVHP411...
  • Page 9: Exploded View

    ATECPOOL SIROCCO HEAT PUMP > User Manual 3. Exploded View Fan protection cover Electrical box 3 Front panel 1 Stand column 2 Controller Fan motor Metal mesh cover 2 Front panel 2 Top cover plate Fin heat exchanger Fixed plate...
  • Page 10: Installation Instructions

    ATECPOOL SIROCCO HEAT PUMP > User Manual III. Installation Instructions WARNING: Only a professional is allowed to install the heat pump. Unqualified users cannot install by themselves, otherwise the heat pump might be damaged and the user's safety will be risked.This section is provided for information purposes only and must be checked and adapted if necessary, according to actual installation conditions.
  • Page 11: Installation Layout

    ATECPOOL SIROCCO HEAT PUMP > User Manual The inlet and outlet water unions can’t stand the weight of soft pipes. The heat pump must be connected with hard pipes! 3. Installation Layout The heat pump is connected to a filtration circuit with a by-pass valve. The by-pass valve should be half-opened (throttled), while all the other valves should be completely opened.
  • Page 12: Electrical Connection

    ATECPOOL SIROCCO HEAT PUMP > User Manual 4. Electrical Connection Power Supply Wires Size Power Supply Wires Model Electricity Supply Cable Diameter Specification AVHP265 380-415V/3Ph/50Hz 5×2.5mm ² AWG 12 AVHP308 380-415V/3Ph/50Hz 5×2.5mm ² AWG 12 AVHP352 380-415V/3Ph/50Hz 5×4.0mm ² AWG 10...
  • Page 13: Running Test

    ATECPOOL SIROCCO HEAT PUMP > User Manual Running Test 1. Inspection Before Running Test a. Please run an inspection test after completing installation; b. Before running test, confirm below items and write √ in the block; ● Unit installed correctly □...
  • Page 14 ATECPOOL SIROCCO HEAT PUMP > User Manual ②Panel Symbol Description Symbol Name Symbol Name Symbol Name Heating Mode On-off Silent Mode Defrosting Cooling Mode Smart Mode Key lock Powerful Mode Down Fault Mode Wi-Fi ③Operation Guideline List Item Operation Way Press the "...
  • Page 15 ATECPOOL SIROCCO HEAT PUMP > User Manual Item Operation Way In the power on state, long press " " for 3 seconds to switch the Choose Mode working mode: heating mode and cooling mode. In the power on interface, press "...
  • Page 16: Fault Code And Solution

    ATECPOOL SIROCCO HEAT PUMP > User Manual Table 1 Code Meanings Water inlet temperature Water outlet temperature Ambient temperature Exhaust temperature Air inlet temperature Outer coil temperature Inner coil temperature Main EEV opening Reserved Compressor current IPM temperature DC bus voltage value...
  • Page 17 ATECPOOL SIROCCO HEAT PUMP > User Manual Communication failure of frequency conversion Er 10 module(alarm when communication between Change PCB. display and PCB is disconnected) 1.Replace the compressor exhaust temperature sensor. 2.Reconnect or clean compressor exhaust Er 12 High exhaust temp protection temperature sensor and wrap it with insulation tape.
  • Page 18: Troubleshooting

    ATECPOOL SIROCCO HEAT PUMP > User Manual Compressor output phase Compressor connection broken, bad Check compressor circuit loss contact Input voltage is too low, pfc module Check input DC bus voltage is low fault voltage,replace module Input voltage is too high, pfc module...
  • Page 19: Wifi Settings

    ATECPOOL SIROCCO HEAT PUMP > User Manual WIFI Settings Software Installation Method 1: Search”Smart life” in your APP store ,install “ ”.Click “GET” to install. Method 2: Scan the QR code below. Click "Create a new user" link to enter the registration method...
  • Page 20 ATECPOOL SIROCCO HEAT PUMP > User Manual When a user enters the registration page, please follow the page prompt to register Follow the prompts to complete the registration User Login: Once the registration is successful, the software will jump to the login screen and enter the correct "user name"...
  • Page 21 ATECPOOL SIROCCO HEAT PUMP > User Manual Open"WLAN" Connect Wi-Fi interne This WIFI is not the WIFI inside the module but WIFI that can be connected to the Internet; After the user logs on to the software, Device binding Click on the top right corner for Make a binding "+"or"Add a device"...
  • Page 22 ATECPOOL SIROCCO HEAT PUMP > User Manual Go to the right interface When select device type,Go to Add "Device Interface". EZ Mode (Default): Press and hold the " " and " " keys at the same time for 3 seconds to enter the distribution network.
  • Page 23 ATECPOOL SIROCCO HEAT PUMP > User Manual Switch to AP Mode Enter the correct Wi-Fi password Click “Comfirm” after input...
  • Page 24 ATECPOOL SIROCCO HEAT PUMP > User Manual Follow tips to connect device hotspots Click to connect to go to Wi-Fi interface, choose the wifi name :SmartLife-xxxx Select and connect and return to the APP interface,Entering the distribution network process...
  • Page 25 ATECPOOL SIROCCO HEAT PUMP > User Manual Wait for the pairing progress to end interface,Entering the distribution network process Add success,Show device Successfully bound devices Click to enter control...
  • Page 26 ATECPOOL SIROCCO HEAT PUMP > User Manual Set temperature selection, which can be set by sliding dots Timing settings, you can set Device operating mode selection timing on or off Switcher control...
  • Page 27 ATECPOOL SIROCCO HEAT PUMP > User Manual...
  • Page 28 ATECPOOL SIROCCO HEAT PUMP > User Manual 106-10000-376...