Page 1
SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual...
Page 2
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP To our customers 1.Dear customers, please read this manual carefully before you install the product, otherwise it may lead to damage to the heat pump or may injure operators as well as cause financial loss. 2.With the development of science and technology, the product will be improved as well, so you are invited to keep up with the latest products.
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Contents 1. Performance data and specifications 1.1 Performance data and feature ……………………………………………………………………………………………… … 1.2 System diagram ………………………………… … … … … … … … … ……………………………………………………… 1.3 Performance data of swimming pool heat pump unit ……………...
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP 1. Performance data and specifications 1.1 Performance and features igh efficiency With a COP value up to 5.0 our heat pumps are very efficient when transferring heat from the air to the swimming pool water. You can save as much as 80% of cost compared to an electrical heater. Long life-span The heat exchanger is made of PVC &...
4. Always keep the heat pump in upright position. If the unit has been tilted, you should wait for at least 24 hours before turning it on . 2.2 Dimensions for Swimming Pool Heat Pump Unit- Monobloc Vertical series Unit:mm Size Unit Model WBR-9.5H-A WBR-11.5H-A WBR-12.5H-A WBR-14.0H-A WBR-17.0H-A WBR-14.0H-A-S WBR-17.0H-A-S WBR-21.0H-A-S...
Page 9
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Unit:mm Size Unit Model 2150 1300 1300 WBR-90.0H-A-S Unit:mm Size Unit Model WBR-135.0H-A-S 1085 1130 2200 2050 WBR-158.0H-A-S...
Page 10
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Unit:mm Size Unit Model WBR-35.0H-A-S WBR-45.0H-A-S 1450 1260 WBR-50.0H-A-S Horizontal series the distance between inlet and outlet Unit:mm Size Unit Model WBR-9.5H-B1 WBR-12.5H-B1 1110 WBR-14.0H-B1 WBR-14.0H-B1-S WBR-17.0H-B1 1110 WBR-17.0H-B1-S the distance between inlet and outlet Unit:mm Size...
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP 2.3 Location of the heat pump The unit will perform well on any location provided three factors are present: 1. Fresh air -- 2. Electricity – 3. Pool filter piping The unit may be installed virtually anywhere outdoors providing minimum distance requirements are met with respect to other objects ( see diagram below) .
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP 2.4 Distance from the pool Normally, the pool heat pump is installed within a 7.5 meter radius of the pool. The greater the distance from the pool, the greater the heat loss from the piping. Since the piping is buried for the most part, heat loss is minimal for distances of up to 30 meters (15 meters to and from the pump= 30 meters total),unless the soil is wet or the water level is high.
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP 2.6 Pool system set up Heat Pump Water processor Side connection valve Outlet Power cable inlet Inlet Condensed water draining pipe Water pump Filter Pool water inlet Draining nozzle Discharge water to pool 2.7 Connecting the by- pass BY-PASS Valve 1...
Therefore, a protection device has been built in, which will interrupt the circuit if the connection has not been performed correctly. Cable diameter(mm ) Voltage(volt) Fuse(A) Nominal current(A) Model (for max.length of 15 meters WBR-9.5H-A 220-240 2x2.5+2.5 WBR-11.3H-A 220-240 11.5 2x2.5+2.5 WBR-12.5H-A...
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP 3. Control the heat pump (LCD) Standby status 3.1 The functions of the wire controller The LCD display ambi ent temp. and current mod e Initialization ROOM VALVE ROOM TEMP TEMP AUTO AU X AU X Press...
Page 17
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Parameter 01 Parameter 00 Desired water temperature in Parameter 02 Desired water temperature in heating mode (15-40℃) Defrosting cycle cooling mode (8-28℃) default setting:40℃ default setting:12℃ Parameter 04 Parameter 03 Evaporator temperature set point Parameter 05 for stopping defrosting (2-30℃...
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP The heat pump's running setting parameter can be set on the wire controller. Please set the parameter according to the below table: Parameter Definition Range Default Remark Ajusted Desired water temperature in cooling mode 8~28℃...
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP Water tem p. Ambien t tem p. Of inlet/ outlet ROOM TEMP TEMP Condenser 1 tem p. Conden ser 2 temp. 3.5 Controller lock Co ntroller lock TEMP AU X Regardless the heat pump is in running or standby status, press at the same time for 3 seconds, all buttons will be locked and display as above.
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP 4. Control the heat pump (LED) Preparation before startup ) Inspection of the heat pump - Check whether the outer appearance of the unit or pipeline system in the unit is damaged during transportation. - Check whether the ventilator fan does not touch any part of the unit.
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP 4.4 How to check parameter setting & measured values of current status In standby or running status press to find parameter 0-A and measured values of current status. Range Parameter Definition Default Remark Ajusted Desired water temperature in cooling mode...
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP 4.5 How to change parameter setting 1. In standby status press to find parameter 0-A and measured values of current status B-F. 2. Press & at the same time for 5 seconds continuously to activate parameter setting. 3.
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP 5.2 Refrigerant gas high and low pressure protection The high pressure protection makes sure the heat pump is not damaged in case of over pressurisation of the gas. The low pressure protection emits a signal when refrigerant is escaping from the conduits and the unit can not be kept running.
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP 6. Direction 6.1 Swimming pool water chemistry Special attention should be paid to the chemical balance of the pool water. The pool water values should always stay within the following limits: Free chlorine(mg/1) TAC(mg/1) Salt(g/1) Important: failure to comply with these limits will invalidate the warranty.
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP 6.4 Check-up Our heat pumps have been developed and built to last, that is, if they have been installed correctly and can run under normal conditions. Regular check-ups are important if you want your heat pump to function safely and efficiently for years on end.
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP 7.2 Trouble shooting guide Improper installation may result in an electrical discharge that could lead to death of-or serious injury to-pool users, installers or others due to electrical shock and may also cause damage to property. DO NOT attempt to modify the internal configuration of the heat pump.
Page 27
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP The heat pump works normally but the water is cooling down instead of heating up Problem The screen displays the temperature but no error codes Observation: Possible cause Solution 1.The wrong mode has been selected 1.Verify the parameters, select the correct mode 2.
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP 7.3 Overview of failure code on display ( LCD CONTROLLER) Wire Running/Failure indicator Protection/Failure Check Solution controller Standby status Running status 1. Check the connection of inlet ☆● 1. Reconnect the sensor. Inlet water temp.
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP 7.4 Overview of failure code on display (LED CONTROLLER) Wire Protection/Failure Running/Failure indicator Check Solution controller Standby status Running status 1. Check the connection of inlet ☆● 1. Reconnect the sensor. Inlet water temp. sensor failure water sensor.
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP 7.5 Overview of protect-300 failure code (3 phase unit) Protect/Failure Wire Controller Protect-300 LED Code System 1 EE01 Low pressure protection System 1 EE01 High pressure protection System 1 EE01 Over current protection System 1 Refrigerant anti-freeze EE01...
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP 8. Wiring diagram WBR-9.5H-B1、WBR-12.5H-B1 、WBR-14.0H-B1 、WBR-9.5H-A WBR-12.5H-A WBR-14.0H-A Wiring diagram R = 5 K R = 5 K POWER SUPPLY POWER SUPPLY...
Page 32
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP WBR-14.0H-B1、WBR-17.0H-B1、WBR- 14.0H-A WBR- 1 7 . 0 H- A Wiring diagram R= 5K STARTING RELAY WBR-17.0H-B1-S、WBR-17.0H-A-S、WBR-21.0H-B1-S、WBR-26.0H-B1-S WBR-21.0H-A-S WBR-26.0H-A-S Wiring diagram 4way valve1 R=5K Current Current Current Current checking checking checking checking B LU R E D B LK WH I R E D...
Page 33
SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP WBR-35.0H-A-S、WBR-45.0H-A-S、WBR-50.0H-A-S Wiring diagram F M 1 F M 2 4way valve1 4way valve1 Y 0 2 Y 0 1 R E D B L K W H I R E D B L K W H I K M 1 K M 2...
Need help?
Do you have a question about the WBR-9.5H-A and is the answer not in the manual?
Questions and answers