GENPOWER GBG 11000E User And Maintenance Manual

GENPOWER GBG 11000E User And Maintenance Manual

Gasoline generators

Advertisement

Quick Links

GASOLINE GENERATORS
USER AND MAINTENANCE MANUEL

Advertisement

Table of Contents
loading

Summary of Contents for GENPOWER GBG 11000E

  • Page 1 GASOLINE GENERATORS USER AND MAINTENANCE MANUEL...
  • Page 2 Information included in this manual may not contain all features belonging to the generator. Genpower has the right of making any amendment to improve the product quality without notifying. GENPOWER GENERATOR “Keep this manual for later assistance”...
  • Page 3 GENPOWER GENERATORS UNIQUE SUPERIOR FEATURES AND ADVANTAGES  Half A Century Old Experience in Generator Production  Low-level Noise  Advanced Technology and High-Quality Diesel Engines  Low-level Exhaust Emission  Advanced Technology and High-Quality Alternators  Low Operating Costs ...
  • Page 4: Important General Information

    IMPORTANT GENERAL INFORMATION Generator Rating Definitions: Genpower generators are produced in compliance with; TS ISO 8528-1, 8528-4, ISO 8528-5, BS500, ISO 3046/1:1985, IEC 60034, NEMA MG-1.22, BS5514/1 standard. Standby Power (ESP) is defined as the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a reliable utility power outage.
  • Page 5 1. PART: SAFETY MEASURES 1.1. INTRODUCTION  Generator groups produced by our company have been designed and conceived by prioritizing all sorts of safety of lives and property.  Generators should be installed and used in accordance with maintenance and operating rules stated in this catalogue both in terms of using the generator economically for a long-term and ensuring continuous safety of life and property.
  • Page 6: Exhaust Gases

     Pull the starter cord slowly until you feel resistance. Then quickly pull the handle to avoid kickback and hand injuries. For safety reasons, make sure that there is no one around the starter.  Check the muffler periodically to make sure it is working properly. Worn leaking muffler should be repaired or replaced. ...
  • Page 7: Filling Oil

    Bandage the burn. Cover the burn with a sterile gauze bandage (not fluffy cotton) 2. PART: BEFORE STARTING:  GENPOWER generators have been produced in international standards.  Each generator has a group identification plate. Serial number, qualifications, weights and manufacturing date of generators are written on this group plate.
  • Page 8: Checking The Oil Level

    Figure 2  Put the oil plug or dipstick in its place. Figure 3 2.2. CHECKING THE OIL LEVEL:  Put the generator on a flat surface.  Remove the dipstick and wipe it with a clean cloth.  Put the dipstick back in place. ...
  • Page 9: Starting Generator

     Purchase the amount of fuel to be used in the 30-day period. This ensures fuel freshness and the required fuel viscosity according to the season.  When unleaded petrol is not available, leaded petrol can be used. Unleaded gasoline prolongs valve life as it reduces combustion residues.
  • Page 10 3.3. Choke Control Arm: Move the manual choke arm to the "CHOKE" position. CHOKE Figure 7 3.4. Throttle Control Lever: The throttle control lever is adjusted and locked in accordance with the frequency of the generator. Do not change the setting except for maintenance time and when it is not deemed necessary. Fast Figure 8 3.5.
  • Page 11: Stopping Generator

    Always have authorized persons or authorized services maintained your generator set. Note that guarantee will be void in case of maintenance, repair and setting made by unauthorized services or persons.  Always use original spare parts in maintenance and repair. Never use non-original parts or those approved by Genpower in written form. ...
  • Page 12  Comply with safety measures mentioned in previous sections while performing the maintenance. ATTENTION! When servicing your generator, disconnect the spark plug wire from the spark plug to prevent the engine from starting suddenly. Disconnect the accumulator, if any. Take safety precautions and follow them. 5.1.
  • Page 13 Figure 14 5.5. Cleaning of Generator:  Remove dirt and debris with a cloth or brush and clean it.  Water jet washing does not recommended due to engine fuel system with alternator winding and electrical equipment may break down. ...
  • Page 14 5.6. Sparking Plug Replacement or Maintenance: Replace or clean the spark plug after every 100 operating hours. Adjust the spark plug gap to 0.76 mm with a feeler (Figure 16). Do not destroy the clean spark plug. Clean the spark plug by scraping or with a wire brush.
  • Page 15 THANK YOU FOR CHOOSING GENPOWER GENERATOR SETS, WE WISH FOR YOU TO USE YOUR GENPOWER GENERATOR THROUGH LONG AGES IN ACCORDANCE WITH THESE OPERATING AND MAINTANCE MANUAL. GENERAL DIRECTORATE ASO II. Industrial Zone 2010. Street No: 18 06909 Temelli-Sincan/Ankara, TURKEY Phone/ Fax: +90(312) 641 32 22 - 641 32 23 genpower@genpower.com.tr...

Table of Contents