5 Service Fixture & Tools
5.1.
When Replacing the Main PCB
After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at "software download" on the "Support Information from NWBG/VDBG-PAVC" web-site in
"TSN system", together with Maintenance software.
5.2.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
No.
Parts No.
1
VFK1442
2
RFKZ0495
3
RFKZ0487
4
RFKZ0343
5
VFK1933
6
VFK2020
7
VFK1175
8
VFK1440
Table S1 Extension Cable List
Connection
FP6004 (MAIN) - EVF UNIT
PS6011 (MAIN) - MOS UNIT
FP6002 (MAIN) - LENS UNIT
PP6002 (MAIN) - PP6401 (FLASH)
PS6003 (MAIN) - LCD UNIT
PS6101 (SUB) - BATT UNIT
FP6402 (MAIN) - REAR CASE FPC
FP6003 (MAIN) - LENS BARRIER
12
Form
21PIN 0.3 FFC
50PIN 0.4 B to B
35PIN 0.3 FFC
30PIN 0.5 B to B
34PIN 0.5 B to B
20PIN 0.5 B to B
16PIN 0.5 FFC
10PIN 0.5 FFC