Huawei BYPASS OP9000 Manual page 17

Table of Contents

Advertisement

BYPASS OP9000
Performance and Features
Specifications
Table 3-2 Specifications of DCP
Front panel
DCP
TO11 TO12
RUN
Specifications
Dimensions:
Board (PCB):169.8 mm (length) x 130 mm (width) x 1.6 mm (thickness)
Front panel:141.5 mm (length) x 19.6 mm (width)
Indicators on the front panel:
Silkscreen
RUN
R11
R12
R21
R22
Document Version
T2-0416xx-20050330-C-1.20
(March 2005)
RI11 RI12
RO1
TI1
Color
Green / Red / Off
Green / Red / Off
Green / Red / Off
Green / Red / Off
Green / Red / Off
HUAWEI TECHNOLOGIES CO.,
TO21 TO22
RI21 RI22
Function
Green – Means Normal or no alarm;
Red – Means Alarm Occurs;
Off – Means out of Power;
Green – Means traffic is on channel 1A;
Red – Means signal loss on channel 1A;
Off – Means no loss of signal while traffic is on channel 1B or
out of power;
Green – Means traffic is on channel 1B;
Red – Means signal loss on channel 1B;
Off – Means no loss of signal while traffic is on channel 1A or
out of power;
Green – Means traffic is on channel 2A;
Red – Means signal loss on channel 2A;
Off – Means no loss of signal while traffic is on channel 2B or
out of power;
Green – Means traffic is on channel 2B;
Red – Means signal loss on channel 2B;
Off – Means no loss of signal while traffic is on channel 2A or
out of power;
LTD.
3 Working Principle and Functions
RO2
TI2
RI11 RI21
RI12 RI22
- 3-7 -