A.13 Electrical connection for appliances with plug
• To connect to the power supply, insert the power cable plug in the corresponding mains socket, first making sure:
– the socket has an efficient earth contact and the mains voltage and frequency match that given on the dataplate. In case of
any doubts regarding the efficiency of the earth connection have the system checked by specialised personnel.
– the system power supply is arranged and able to take the actual current absorption and that it is correctly executed according
to the regulations in force in the country of use.
• The plug must be accessible after positioning the appliance in the place of installation.
• The plug must be in a position always visible to the operator performing the intervention during maintenance operations.
A.14 Electrical connection for appliances with cable without plug
• The connection point has an efficient earth contact and the mains voltage and frequency match that given on the data plate. In
case of doubts regarding the efficiency of the earth wire, have the system checked by specialised personnel.
• The appliance must be permanently connected to the power supply, respecting the polarities:
– brown/black
2
/gray
– yellow/green: earth
– blue: neutral
• An H05VV-F type power cable (code 60227 IEC 53) is used for the permanent connection to the mains; in case of replacement,
use a type with at least these characteristics. When replacing the cable, the earth wire must be kept longer than the live and
neutral wires.
• The differential thermal-magnetic switch must be lockable in the open position in case of maintenance.
• If using a plug, it must comply with the national installation rules. The plug must also be:
– accessible after the appliance has been positioned
– in the place of installation;
– in a position always visible to the operator performing the intervention during maintenance operations;
A.15 Positioning
• Install the appliances, taking all the safety precautions required for this type of operation, also respecting the relevant fire-
prevention measures.
2.
present only in appliances with three-phase power supply
24
2M Mass Freezer 2 full doors R290
2M Gab Freezer 2 full doors R290
2M 2T Mass refrigerator/freezer 900+300L R290
2M 2T Mass refrigerator/freezer 600+600L R290
2M 2T Gab refrigerator/freezer 900+300L R290
2M 2T Gab refrigerator/freezer 600+600L R290
1M Mass freezer full door R290
1M Mass freezer glass door R290
1M Gab freezer full door R290
1M Gab freezer glass door R290
1M 2T Mass refrigerator/freezer 300+300L R290
1M 2T Gab refrigerator/freezer 300+300L R290
1M Mass freezer full door R404a
1M Mass freezer glass door R404a
1M Gab freezer full door R404a
1M Gab freezer glass door R404a
1M 2T Mass refrigerator/freezer 300+300L R404a
1M 2T Gab refrigerator/freezer 300+300L R404a
2M Mass Freezer 2 full doors R404a
2M Mass Freezer 2 glass doors R404a
2M Gab Freezer 2 full doors R404a
2M Gab Freezer 2 glass doors R404a
2M 2T Mass refrigerator/freezer 900+300L R134a/R404a
2M 2T Mass refrigerator/freezer 600+600L R134a/R404a
2M 2T Gab refrigerator/freezer 900+300L R134a/R404a
2M 2T Gab refrigerator/freezer 600+600L R134a/R404a
2
: phase
Description
Maximum
impedance
permitted (Ohm)
0,307 Ohm
0,396 Ohm
0,390 Ohm
0,3031 Ohm
0,2976 Ohm
0,2733 Ohm