OWL Intuition-lc Getting Started

Electricity consumption monitoring
Hide thumbs Also See for Intuition-lc:

Advertisement

Quick Links

Electricity consumption monitoring – three phase
for larger homes and light commercial premises
IN THE BOX:
Transmitter unit
3 channel
© 2 Save Energy Limited 2014
Getting started with
x 3
WARNING
- RISK OF ELECTRICAL SHOCK
- Please Refer to User Manual.
MADE IN CHINA
MODEL : CMA116
3 x plug-in standard
Sensor clamp
(<10mm cable, <71A)
OR
3 x plug-in large
Sensor clamp
(<17mm cable, <200A)
3 x AA
alkaline battery
1

Advertisement

Table of Contents
loading

Summary of Contents for OWL Intuition-lc

  • Page 1 Getting started with Electricity consumption monitoring – three phase for larger homes and light commercial premises IN THE BOX: 3 x plug-in standard 3 x AA Sensor clamp alkaline battery (<10mm cable, <71A) 3 x plug-in large Sensor clamp (<17mm cable, <200A) WARNING - RISK OF ELECTRICAL SHOCK - Please Refer to User Manual.
  • Page 2 Introduction This Electricity Transmitter is a part of the OWL Intuition range of cloud connected moni- toring and control products. Its operation is dependant upon being paired to the broad- band Internet connected Network OWL (supplied separately). This version of the Electricity Transmitter is designed for monitoring three phase electric- ity consumption.
  • Page 3: Installation Instructions

    STEP THREE - Log in and follow Wizard. • If this is a new Intuition installation then you will first need to install the Network OWL (supplied separately). For full details please refer to the Network OWL installation...
  • Page 4 Intuition account. For full details please refer to the Network OWL installation guide supplied with that product, however a summary of the steps are listed below: Using a web browser visit https://www.owlintuition.com Click “Create Account”. Check and confirm that the Network OWL is online.
  • Page 5 You can quickly check for correct pairing at any time by pressing the Transmitter “Check” button until the red LED starts flashing - if the Transmitter red LED and Network OWL blue LED flash within a fraction of a second of each other, they are correctly paired.
  • Page 6 • Adjust consumption Voltage and Power Factor settings to measured values if available. If in doubt leave the default values (Voltage = 230; Power Factor = 1.0) and click “Next”. Please note that this voltage is the phase to neutral voltage and is hence 230V rather than 400V (phase to phase voltage).
  • Page 7 Using the latch, clamp the 3 Sensors around the insulated Live cables going into the meter as per the table below – Live cables either side of meter is acceptable. Phase (Line) IEC 60446 Pre 2004 OWL Transmitter Number Wire Colour IEE Colour Socket...
  • Page 8 - Please Refer to User Manual. P3 / L3 Sensor Sensor Neutral P1 / L1 P2 / L2 P3 / L3 Utility Meter Blue Brown Black Grey Alternative Sensor Locations Intuition-lc Electricity Grid Transmitter & Sensor Installation © 2 Save Energy Limited 2014...
  • Page 9 STEP FIVE - Log in to your OWL Intuition account If you are not already, please log in to your OWL Intuition account with your username and password at: https://www.owlintuition.com • You should now have an Electricity and 3 Phase widget within your web dashboard.
  • Page 10 Transmitter. • The Network OWL should ideally be hung on the wall in a free area as far from large metal objects as possible. Position the antenna in a vertical orientation. •...
  • Page 11 Unless the Transmitter is in Check Mode, the red LED does not flash, in order to pro- long battery life. • Check that the blue LED on the Network OWL flashes at least every 12 seconds if the monitored electricity supply consumption is varying, or every 60 seconds when at a steady state.
  • Page 12: Safety Information

    SAFETY INFORMATION To ensure that you use your product safely and correctly please read the warnings & safety precautions below before installing your OWL Intuition Transmitter & Sensor. • This product uses a Type C current Sensor. Do not apply around or remove from haz- ardous LIVE conductors.
  • Page 13: Caring For Your Product

    materials or explosives. • Remove the batteries before storing the product for extended periods. • Only use fresh batteries. Do not mix new and old batteries. • Do not dispose of old batteries as unsorted municipal waste, only do so in accordance with your local waste disposal regulations.
  • Page 14: Specifications

    The CE marking certifies that this product meets the main requirements of the European Parliament and Council Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request. OWL Intuition products are manufactured to ISO-9001 Quality Assurance Standards.
  • Page 15: Warranty Information

    WARRANTY INFORMATION 2 Save Energy Limited guarantees that OWL Intuition products will work for a minimum period of 24 months from date of purchase and that it will be free from defects in materials, workmanship or design. If during this limited 2 year period of guarantee, from date of purchase, you find that the equipment is not working properly, you may return it to us and we will replace, or, (at our discretion) repair it, free of charge.
  • Page 16 For details on using your new OWL Intuition-lc system, please download the Electricity Monitoring User Manual document by clicking on Manuals on the web dashboard (lower right). Customer Support If you have any further questions please check our knowledge base at: https://theowl.zendesk.com...