Electricity consumption monitoring – three phase
for larger homes and light commercial premises
IN THE BOX:
Transmitter unit
3 channel
© 2 Save Energy Limited 2013
Getting started with
x 3
WARNING
- RISK OF ELECTRICAL SHOCK
- Please Refer to User Manual.
MADE IN CHINA
MODEL : CMA116
3 x plug-in standard
Sensor clamp
(<10mm cable, <71A)
OR
3 x plug-in large
Sensor clamp
(<17mm cable, <200A)
3 x AA
alkaline battery
1

Advertisement

Table of Contents
loading

Summary of Contents for OWL Intuition-lc

  • Page 1 Getting started with Electricity consumption monitoring – three phase for larger homes and light commercial premises IN THE BOX: 3 x plug-in standard 3 x AA Sensor clamp alkaline battery (<10mm cable, <71A) 3 x plug-in large Sensor clamp (<17mm cable, <200A) WARNING - RISK OF ELECTRICAL SHOCK - Please Refer to User Manual.
  • Page 2 Introduction This Electricity Transmitter is a part of the OWL Intuition range of cloud connected moni- toring and control products. Its operation is dependant upon being paired to the broad- band Internet connected Network OWL (supplied separately). This version of the Electricity Transmitter is designed for monitoring three phase electric- ity consumption.
  • Page 3: Installation Instructions

    The Network OWL should already be installed. Refer to the Network OWL Getting Started guide for guidance if required. Check that it is powered-up and connected to the OWL servers (the top green LED should be flashing in a “triple blip pattern”).
  • Page 4 LED on the front will start flashing every 2 seconds (for 30 seconds). • The pairing process will now take place and the blue LED on the Network OWL will start flashing a fraction of a sec- ond after the red LED flashes on the Transmitter. PRESS •...
  • Page 5 You can quickly check for correct pairing at any time by pressing the Transmitter “Check” button until the red LED starts flashing - if the Transmitter red LED and Network OWL blue LED flash within a fraction of a second of each other, they are cor- rectly paired.
  • Page 6 Plug the Sensors into the associated Transmitter socket. • The Transmitter should be hung on the wall in a free area as far from large metal objects as possible. Phase (Line) IEC 60446 Pre 2004 OWL Transmitter Number Wire Colour IEE Colour Socket Brown 1 - Left...
  • Page 7 - Please Refer to User Manual. Sensor P3 / L3 Sensor Neutral P1 / L1 P2 / L2 P3 / L3 Utility Meter Black Grey Blue Brown Alternative Sensor Locations Intuition-lc Electricity Grid Transmitter & Sensor Installation © 2 Save Energy Limited 2013...
  • Page 8 Now enter the remaining information again, as requested (refer to the Network OWL Getting Started guide if you need an explanation of the information required). • Ensure your Network OWL is still online (the top green LED should be flashing in a “triple blip pattern”) •...
  • Page 9: Signal Strength Indicator

    STEP FIVE - Log in to your OWL Intuition account Please now log in to your OWL Intuition account with your username and password at: https://www.owlintuition.com • You should now have an Electricity and 3 Phase widget within your web dashboard.
  • Page 10 Transmitter. • The Network OWL should ideally be hung on the wall in a free area as far from large metal objects as possible. Position the antenna in a vertical orientation. •...
  • Page 11 Unless the Transmitter is in Check Mode, the red LED does not flash, in order to pro- long battery life. • Check that the blue LED on the Network OWL flashes at least every 12 seconds if the monitored electricity supply consumption is varying, or every 60 seconds when at a steady state.
  • Page 12: Safety Information

    SAFETY INFORMATION To ensure that you use your product safely and correctly please read the warnings & safety precautions below before installing your OWL Intuition Transmitter & Sensor. • This product uses a Type C current Sensor. Do not apply around or remove from haz- ardous LIVE conductors.
  • Page 13: Caring For Your Product

    materials or explosives. • Remove the batteries before storing the product for extended periods. • Only use fresh batteries. Do not mix new and old batteries. • Do not dispose of old batteries as unsorted municipal waste, only do so in accordance with your local waste disposal regulations.
  • Page 14: Specifications

    The CE marking certifies that this product meets the main requirements of the European Parliament and Council Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request. OWL Intuition products are manufactured to ISO-9001 Quality Assurance Standards.
  • Page 15: Warranty Information

    WARRANTY INFORMATION 2 Save Energy Limited guarantees that OWL Intuition products will work for a minimum period of 24 months from date of purchase and that it will be free from defects in materials, workmanship or design. If during this limited 2 year period of guarantee, from date of purchase, you find that the equipment is not working properly, you may return it to us and we will replace, or, (at our discretion) repair it, free of charge.
  • Page 16 For details on using your new OWL Intuition-lc system, please download the Electricity Monitoring User Manual document by clicking on Support & Manuals on the web dashboard (lower right). Customer Support If you have any further questions please check our frequently asked questions at: http://www.theowl.com/faqs.html...