TROUBLESHOOTING ERROR CODES
NOTE- Turn off power to water heater.
• With anode power wire disconnected, insert one meter lead
into the wire as shown.
• Locate the anode control module.
48
• Disconnect the anode power lead harness from the anode
control module.
• Insert your other meter lead into the molex connector
location for the wire associated with the suspect anode
as shown in bottom photo.
• Resistance reading should be less than 20 ohms. If
reading is higher than 20 ohms replace wiring harness.
NOTE- The anode rod power wire harness has 4 wires in the
molex.
TRITON HD
GREEN = GROUND
RED = UPPER ANODE
BLUE = MIDDLE ANODE
ORANGE = LOWER ANODE
TRITON SD
GREEN = GROUND
YELLOW = UPPER
GRAY = MIDDLE
RED = 4TH
BLUE = LOWER