Rheem TRITON GHE80SS Service Training Manual page 32

80, 100 & 119 gallon ultra-high efficiency water heaters
Hide thumbs Also See for TRITON GHE80SS:
Table of Contents

Advertisement

Rheem TRITON
TM
Service Manual
ERROR CODES
Error Code
T114
T115
T116
T117
T118
T119
T120
T121
T122
T123
T125
T126
T127
T128
T130
T131
T132
T133
T135
T136
T137
T140
T141
T142
T150
T151
T152
T504
32
Display
T114 Flame Rod Degraded and Needs Servicing
T115 Combustion Health Degraded: Needs Service
T116 Combustion Health Degraded. Needs Service
T117 Time to Drain and Inspect Tank
T118 Time to Check Venting for Debris
T119 Time to Clean Out the Condensate Drain Trap
T120 Time to Replace the Neutralizer
T121 No water Detected in Tank
T122 Powered Anode Control Comm Failure
T123 Upper Anode Open
T125 Upper Anode Shorted
T126 Upper Anode Overload
T127 Upper Anode Pre-Overload
T128 Middle Anode Open
T130 Middle Anode Shorted
T131 Middle Anode Overload
T132 Middle Anode Pre-Overload.
T133 Lower Anode Open
T135 Lower Anode Shorted
T136 Lower Anode Overload
T137 Lower Anode Pre-Overload
T140 Anode 4 Shorted
T141 Anode 4 Overload
T142 Anode 4 Pre-Overload
T150 Percentage of Successful Ignition is Low
T151 Flame Current Deviation is High
T152 Blower Motor Deviation is High
T504 WiFi Chip Communication Error