8
Following are specifications for the iSTAR Pro 4U Rack Mount:
Physical
Dimensions (H x W x D)
Space Requirements
Environmental
Weight
Misc. Alarms
Temperature Alarm
Electrical
Power Requirements
Power
Heat Dissipation (Typical)
AC Input Circuit Breaker
Rating
UPS Operation
Memory and RTC Backup
Max Lock Power (Total
Output)
Individual Lock Current Limit
Lock Relay Ratings
TABLE 3. Physical Specifications
18 x 48 x 74 cm
(7 x 19 x 29 in)
4U (standard rack units)
0° to 50° C (32° to 122° F),
5 to 95% relative humidity, non-condensing
34 kg (74 lbs)
Fan failure
, High temperature
60° +/- 6°C, (140° +/- 10°F)
TABLE 4. Electrical Specifications
115 VAC, 60 Hz, ± 10%
5A @600W
500 BTU/h
15A
Battery charging included, with optional
17Ah batteries (5) provides nominal four hours
backup time; 48 hour recharge time
On-board rechargeable NimH batteries provide
minimum 12 hours retention of RAM and RTC
(Real Time Clock)
16A
2.5A
250,000 cycles

Advertisement