TB2
5
When using kill input, connect 0 VDC. When kill is deactivated (0 VDC is connected),
the door will act according to current input status. When kill is activated (0 VDC is
disconnected), the door will close immediately if not already closed. Hold open and
low pass filter timers are reset. Key impulse will open lock during activated kill if key
impulse is connected to TB2 7 and 8.
6
When using kill input, connect 24 VDC.
7
0 VDC
8
Key impulse
9
0 VDC, lock control
10
24 VDC for lockcase. Max. 375 mA. *)
11
0 VDC
12
24 VDC for impulse devices *)
13
MVI impulse
14
Outer impulse
*) Max. total 700 mA
TB1
1
Motor Control. Connect to passive door TB6:1.
2
0 VDC. Connect to passive door TB6:2.
3
Slave control. Connect to passive door TB6:3.
4
24 VDC. Connect to passive door TB6:4.
24
TB2
5 6 7 8
9 1011121314
TB1
1 2 3 4