Bosch LHN-UC15L-SIP User Manual page 35

Table of Contents

Advertisement

LHN‑UC15L‑SIP | LHN‑UC15W‑SIP | AMN‑P15‑SIP
Device test
Use the Device test action to define a test to see if the device is performing correctly. Select
the type of device test to run when a trigger initiates.
NOTE: The Loopback horn mic is only applicable when using the IP Horn loudspeaker.
You can also define a GPO Action that runs when the trigger action is present.
Notice!
Device tests run to completion no matter what state the Trigger starts but does not stop the
i
action check box shows.
The results of the device test can be provided via the API. The result can be read out via <ip>/
api/ext/v1/status - value "speakertest" (TRUE = passed, FALSE = failed).
Route call
Use the Route call action type for the device to accept and route an incoming SIP call (this
setting works only if the trigger is a SIP call). You can define the call routing to be full duplex
(audio goes both ways) or speaker only (audio goes one-way).
Full duplex audio mode (IP Horn loudspeaker only) utilizes the integrated microphone of the
device establishing a two-way audio connection with the SIP caller. This means that a person
standing near the device can converse with the person at the other end of the SIP call.
Speaker only audio mode means the SIP call is the only audio heard over the device. Speaker
only is a one-way call/announcement to the device.
You can also define a GPO Action that runs when the trigger action is present.
Notice!
i
There is no possibility to initiate a SIP call from the device to another SIP device.
Set routing
Use the Set routing action type to configure the device's audio output. There are two audio
output channels: line out and speaker out. You can configure each channel independently with
its own input source which gives greater flexibility in routing audio.
Available input source: no audio (silence), audio line input, and sine generator. If using the
sine generator, you may adjust the sine signal in the Audio page.
SIP calls and playing messages are automatically routed to both line out and speaker out.
GPO Action
In addition to a running action, you can configure an additional physical GPO or virtual GPO to
occur. For example, every time a live call or message is transmitted, a GPO is used to activate
a separate light (an optical signal).
The device has 1 physical GPO which may be connected using a separate cable and 16 virtual
GPOs, which can been seen on Maintenance, page 37 , under API interface.