en | Installation
2.2.4

Physical reset button

Reference view
Figure 2.6: Test/Reset button and LED
Test/Reset button (Figure 2.6, callout 1)
There is a physical button for test and reset purposes (Figure 2.6, callout 1). Use a paper clip
or similar object to press and hold the Test/Reset button. This button will perform different
actions depending on how long you press it:
1.
2.
Indication LED (Figure 2.6, callout 2)
The LED (Figure 2.6, callout 2) next to the Test/reset button serves as a time indicator of how
long the Test/reset button is pressed. Once you click the Test/Reset button once, the LED
lights up every five seconds for as long as you keep the button pressed, and once more when
you let go of the button to indicate the reset is applied.
2023.02 | V01 | F.01U.389.835
Press and hold for 6 - 10 seconds: the IP address of the IP Amplifier module will reset to
factory default;
Press and hold for 11 - 20 seconds: the IP Amplifier module will reset to factory default.