1.2 Technical parameters
Cutting head
Laser wavelength:
Laser power:
Fiber interface:
Spot magnification:
Focus adjustment range:
NA:
Centering adjustment range:
Focus acceleration:
Cutting gas interface:
Nozzle cooling gas connection:
Water cooling interface:
Operating temperature:
storage temperature:
size:
weight:
Notice:
To avoid damage to the cutting head during storage and transportation, pay attention to
the following:
The cutting head should be stored within the allowable temperature and humidity
range.
Avoid storage in and near magnetic fields such as permanent magnets or strong
alternating fields.
Avoid collision of the cutting head.
BLT441T Product Manual
BLT441T
1030-1090nm
≤15kW
QBH/QD/Q+/ADD
M=2.1 (100:210)
±50mm (optical ratio 1:2 100:200)
Max.0.13 at Fc100
±1.5mm
7.5m/s²
ø10, maximum 25bar (2.5Mpa)
ø6, maximum 5bar (0.5Mpa)
ø8, maximum 5bar (0.5Mpa), minimum flow 2.0l/min
5~55℃
-25~+55 ℃
404x122
About 5.5kg
2