8) Install the humidistat on the wall where it is open to the cellar and can be read easily,
approximately 60" above the floor. See section on Humidistat Mounting on page 18.
9) Plug transformer plug into wall outlet. The humidifier should now be operational.

Wine Guardian-Mounted (Integrated Installation)

NOTE: Integrated humidifiers can be mounted on either of the two side openings of
the cooling unit on the cooling or evaporator end only. If a duct connection is in that
position, move the duct connection to the top or other side.
DO NOT MOUNT THE HUMIDIFIER ON THE CONDENSER END OF THE UNIT.
1) Remove Drip Pad from plastic bag and install in unit by lifting up on the spring-loaded
drip tray. (See Fig 7.0 on page 22)
Note: The pad must be installed in the correct position. The pad must be installed with the
colored spot "Up", next to the drip tray.
Swing the drip tray and drip pad back to a vertical position to finish the assembly of the drip
pad.
2)
Attach the access panel and rotate (2) captive latches to secure the access panel to the
humidifier housing.
3) Remove side access panel on the side of the cooling unit where you wish to mount the
humidifier.
4) Select the proper adapter plate for the cooling unit. Models D200 and SS200 for 60Hz
and WG175 for 50Hz units require a larger adapter plate and install on the side opening
using the screws from the panel removed above. The adapter plate allows the humidifier
to be mounted in either a forward position or back toward the center by simply rotating
the adapter plate 180 degrees. (See Figure 5.0)
5) Install a ½" (1.27cm) flexible drain line from the bottom of the humidifier to an open
drain or connect into the drain line from the cooling unit.
6) Install a ¼" (.635cm) warm water line from the water supply to the connection at the top
of the humidifier. A shut off valve (not provided) is recommended to isolate the
humidifier from the water system when needed.
7) Connect the communication cable to the side of the Wine Guardian system as shown in
Figure 6 on the following page. The communication cable provides power and control
signals to the humidifier from the Wine Guardian main control panel.
8) Proceed to set-up of Remote Interface Controller within the wine cellar to re-program for
humidity control
15