Freestanding Installation - Wine Guardian 99H0174-00 Installation, Operation And Maintenance Manual

Wine cellar cooling systems
Table of Contents

Advertisement

Freestanding Installation

1) Remove Drip Pad from plastic bag and install in unit by lifting up on the spring-loaded drip
tray. (See Fig 7.0 on page 22)
Note: The pad must be installed in the correct position. The pad must be installed with the
colored spot "Up", next to the drip tray.
Swing the drip tray and drip pad back to a vertical position to finish the assembly of the drip
pad.
2) Attach the access panel and rotate (2) captive latches to secure the access panel to the
humidifier housing.
3) Determine where unit will be mounted.
a. If wall mounted, use surface mount unit (99H0185-01 for 60Hz and 99H0186-01 for
50Hz) Secure bracket to wall (Refer to Fig. 4 on page 12). Attach humidifier to the
bracket (with drain tube on bottom) using four (4) screws provided.
b. If shelf mounted, place humidifier on shelf with drain tube on bottom. You may need to
drill a 1" (2.5cm) diameter hole in the shelf and route the drain tube through the hole.
c. If through-the-wall mounted, frame opening to have studs 16" (40.6cm) OC (on center).
Attach the Through-the-Wall (99H0185-00 for 60Hz and 99H0186-00 for 50Hz) to the
studs using drywall screws or something similar. Attach humidifier (with drain tube on
the bottom) to the bracket using the eight (8) screws provided. Fill in any gaps between
the humidifier and the wall framing with insulation. Trim as necessary.
4) Install a ¼" (.635cm) water line from the water supply to connection at the top of the
humidifier. A shut-off valve (not provided) is recommended to isolate the humidifier from
the water system when needed.
5) Install a ½" (1.2cm) flexible drain line from the bottom of the humidifier to an open drain or
connect into the drain line from the cooling unit.
Proceed to Steps 4 & 5 for humidifier part number:
- 99H0174-00 and 99H0174-01 (60Hz)
- 99H0176-00 and 99H0176-01 (50Hz)
Proceed to Steps 6 and 7 for humidifier part number:
- 99H0185-00 and 99H0185-01 (60Hz)
- 99H0186-00 and 99H0186-01 (50Hz)
6) Humidifier part number 99H0174-00 uses the Remote or Local Interface Controller at the
Wine Guardian system to monitor and control humidity. Plug communication cable from
humidifier into connection at Wine Guardian unit at this time. The communication cable
provides power and control signals to humidifier from Wine Guardian main control panel.
7) Proceed to set up of the Remote or Local Interface Controller at Wine Guardian unit to re-
program for humidity control.