5. Hard Wire Installation

WARNING: Risk of electrical shock. Make sure the power
has been disconnected before performing the following
procedures.
Loosen the terminal block screws and remove the wires from the
top terminal block.
Loosen the outside nut of the strain relief and remove the power
cord.
Put the supply wires through the strain relief and connect to the
top terminal block.
NOTE: If a hard wired installation is required, the strain relief may
need to be replaced depending on wire used.
Tighten the nut on the strain relief.
Replace the cover, and install and tighten the five screws.
Turn on the AC supply power.
Secure any extra wire under the counter.
IMPORTANT! The area in front of the sensor must be free of
objects during the two minute learning cycle or the faucet may not
function properly.
Allow two minutes for the sensor to cycle through the automatic
sensing distance.
Kohler Co.
Secure any excess
wire under counter.