Room temperature
External temperature
* Models with low-temperature cooling systems

2.4 - SELECTION OF POSITION OF THE INSIDE UNIT

To obtain the best operating performance and prevent faults or hazardous conditions, the position of indoor
unit installation must meet the following requirements:
a. Do not expose the indoor unit to heat or steam.
b. Make sure that the space to the right and left is at least 120 mm and space above the unit is at least 150
mm. (figure 1).
c. The indoor unit must be installed at a minimum height of 2 metres and maximum of 3 metres from the
floor.
d. The wall where the indoor unit is to be fixed, must be stable, strong and suitable to support the weight.
e. There must be no obstacles for the free circulation of air both from the inlet side and especially the outlet
side. In particular, there must be no obstacles within a distance of 2000 mm.
A shorter distance could cause turbulence such to prevent correct operation of the appliance.
f. If possible, install the unit on an outdoor wall, in a way to be able to convey condensate draining to the
outside.
g. The indoor unit must not be in a position such that the air flow is aimed directly at the persons below
(figure 3).
h. The indoor unit must not be installed directly above household appliances (television, radio, refrigerator,
etc.) or above a heat source (figure 2).
i. Install the indoor unit in a way that there are no obstacles, which do not allow the signals emitted by the
remote control to be received (figure 4).

2.5 - INSTALLATION OF THE INSIDE UNIT

2.5.1 - Installation of fastening plate

After having checked that described in paragraph "2.2", assemble the fixing plate (7) taking the dimensions
stated in figure X1 into consideration.
a. Position the plate against the wall.
b. Mark the drilling points, making sure that they are level.
c. Make the holes necessary in the wall using a suitable bit.
Make sure there are no pipes or electric ducts in the drilling area.
d. Insert the plugs (4) into the holes and fix the plate (7) to the wall using the screws (3) supplied (figure 5).
Using a spirit level, make sure that the fixing plate (7) is level.
e. If the wall is in wood, use relevant countersunk-head screws (not supplied).
f. Check the stability of the plate (7), moving it laterally and vertically.

2.5.2 - Realisation of pipe passage holes

If the connection lines arrive from the rear right of the indoor unit, a hole "R" must be made for passage of
the piping, as successively described (see figure X1).
EN - 10
Cooling Mode
17°C - 32°C
0°C - 50°C
-15°C - 50°C *
Heating Mode
Dehumidification Mode
0°C - 30°C
-15°C - 30°C
10°C - 32°C
0°C - 50°C