JB-FSD-9082 Fire Indicating Panel
-
-----------
Please read this operation manual carefully before installing and using the product.
. Introduction
JB-FSD-9082 Fire Indicating Panel(hereinafter referred to as Fire Indicating
Panel)is a microprocessor-controlled fire indicating panel, which is developed
and produced by Fanhai Sanjiang. The fire indicating panel is connected with
fire alarm control panel through RS485 bus line. Each floor can be installed with
a fire indicating panel , and when a detector or module triggers the alarm, the fire
indicating panel will emit a sound and light alarm, meanwhile the relevant fire
alarm information will be displayed on the screen.
. Features
Beautiful and elegant appearance
Easy to operate, easy to install
With a stable and reliable communication
of RS485 bus , and the maximum length of
the bus is over 1,000 meters
. Technical Parameters
Voltage:DC 24V±20%
Current:monitor state ≤ 32mA,alarm state ≤ 66mA
Standard:GB 17429-2011《Fire Indicating Panel》
Capacity:single fire indicating panel can display up to 99 pieces of
information
Wiring system: five-wire system, power cord (+24V, GND), 485 bus (A,
B), PE line( ).
Operating environment:
indoor;
temperature:-10℃~+50℃ (14
relative humidity:≤95% RH (40℃,non-condensing);
Dimensions:210.0mm×150.0mm×33.5mm
Weight:0.5KG
. Appearance
The Figure 1 below illustrates overall dimensions of the panel.
and Dimensions
℉ ;
~ 122 )
Version:504600180308
-----------

Advertisement

loading

Summary of Contents for SANJIANG JB-FSD-9082

  • Page 1 JB-FSD-9082 Fire Indicating Panel(hereinafter referred to as Fire Indicating Panel)is a microprocessor-controlled fire indicating panel, which is developed and produced by Fanhai Sanjiang. The fire indicating panel is connected with fire alarm control panel through RS485 bus line. Each floor can be installed with...
  • Page 2: P Roduct Usage

    Figure 1 Dimensions Ⅴ roduct Usage 1. Terminal description: +24V:positive power input GND:negative power input A:signal terminal 485A B:signal terminal 485B :PE 2. Wiring diagram: +24V SEC3002 JB-FSD-9082 JB-FSD-9082 JB-FSD-9082 Figure 2 Wiring Diagram 2...
  • Page 3 : Function introduction and usage 1) Indicators Indicator Color Description The power green indicator light is always POWER green on when the power supply is normal. FIRE Lights when there is a fire alarm. Normally for flashing state, long time COMM.
  • Page 4 address, display mode, display language and self-check. After the operation is completed, return to the normal operation interface, press the ENTER key to close the keypad lock and turn off the display. (2) Self-test function After the key is unlocked, press the SELF-TEST key, and the fire indicating panel begins to self-check.
  • Page 5 setting, press the ENTER button to save the Settings. (1) address setup After entering address setting ADD:01 interface, as shown in Figure 6, "01" indicates the local address number. Press the left and Figure 6 local right key to move the cursor around, press the address setup MUTE key the number add one,while press the SELF-TEST key it subtract one.
  • Page 6 3) Align the guide groove on the back of the fire indicating panel with the guide rail of the base and press the panel downwards along the wall until the guide groove on the back of the fire indicating panel fits the base fully. Then tighten the hook on the back of the panel and the guide piece of the fixed base with supporting screws (as shown in Figure 10).
  • Page 7: Fault Analysis And Troubleshooting

    3. Debugging method 1) After all the products are installed and confirmed, turn on the power of the fire alarm control panel, set address number for the installed fire indicating panel, and register the corresponding fire indicating panel on the fire alarm controller. At the same time according to the physical location of the fire indicating panel, configure the properties of the panel, such as districts, blocks, floors, rooms and other information.
  • Page 8 Attention 1. Check whether there are any problems with the line before waking up the machine, such as short circuit, open circuit, wrong connection, etc. 2. The fire indicating panel is a precision electronic product, which needs to be managed by a special person. 3.