Nortel 5399 User Manual page 48

Remote access concentrator
Hide thumbs Also See for 5399:
Table of Contents

Advertisement

Chapter 1
Network Administration
Model 5399 Remote Access Concentrator Network Administrator's Guide for UNIX
A-44
Table B-14. Fields in the stats –T Command Display (Continued)
Field
Description
Circuit ID
The T1/PRI engine's Circuit ID displayed from the
tni_circuit_id parameter.
Loopback
The loopback status has the following possible states:
mode
Loopback – Loopback is in progress.
No Loopback – There is no loopback in progress. The
test LED on the front panel is not illuminated.
Number of
Part of the current report that indicates the number of
Valid Seconds
seconds for which statistics data has been collected.
CRC6 Error
A CRC6 error occurs when the six-bit CRC field
Event
calculated by the customer installation, based on the
incoming DS1 signal, does not agree with the CRC field
contained in the DS1 signal received from the network.
Out of Frame
An Out of Frame (OOF) event begins when any two of
four consecutive frame synchronizing bits are received
from the network interface. An OOF state ends when
reframe occurs.
ESF Error
An Extended Superframe CRC error.
Event
Errored
An Errored Second is a second with one or more ESF
Seconds
error events, that is, one or more CRC error events or one
or more Out of Frames (OOFs).
(continued on next page)
Book A

Advertisement

Table of Contents
loading