36 SFP specifications
Parameter
Distance
Line code
The T1 SFP uses an RJ-48C connector (see the following figure), which is
similar to an RJ-45 connection, but with different pinouts.
Figure 6
RJ-48C connector
The following table describes the RJ-48C pinouts.
Table 1
RJ-48C pinouts
Pin
1
2
3
4
5
6
7
8
The T1 equipment at the far end of the T1 connection must also use
an RJ-48C jack. After the pinout of the RJ-48C jack at the far end is
determined, determine if a straight-through or crossover cable is required.
An off-the-shelf straight-through cable can be used to directly connect the
T1 SFP module and the far-end T1 equipment if the far end has the pinout
shown in the following table.
Copyright © 2007, Nortel Networks
.
Specification
Up to 2874 m over 22 AWG cable. The distance may
be reduced when 24 AWG UTP CAT5/5E cable is
used.
Binary 8 Zero Substitution (B8ZS) or Alternate Mark
Inversion (AMI)
Description
Receive ring
Receive tip
Receive shield
Transmit ring
Transmit tip
Transmit shield
Not used
Not used

Ethernet Routing Switch 4500 Series

Installation — SFPs and XFPs

NN47205-301 (324186-A) 01.04 Standard

5.1 6 December 2007