4. Troubleshooting
4-2 Electrical Malfunction
(Continued)
RF radiant element
(No heating or
Abnormal working)
*Check RF radiant element
*Check whether wire harness is not
damaged and connected correctly
to RF radiant element.
Assembly RF Cooktop
*Check resistance on terminals
of RF radiant element.
END
This document can not be used without Samsung's authorization.
No
Yes
Yes
47
*Repair or replace damaged harness
END
WARNING
It is very dangerous to disconnect wire harness
when heater element is in operation.
Fig.6 RF radiant element resistance values
Position
ohms
1b-2b
2a-"A"
2a-"B"
2a-"C"
Fig.7 The radiant heater harness connections
Position
Color
"A"
orange
"B"
yellow
"C"
blue
2a
brown
1b
black
2b
yellow