4. Troubleshooting
4-2 Electrical Malfunction
Troubleshooting (PCB failure)
PCB Failure
- Check the input voltage of
PCB SMPS (input check-
point : 120V )
OK
- Check the output voltage of
PCB SMPS (Output check-
point : 5V/12V )
OK
Do all relays operate?
OK
Check the Assy-Inverter Module & Assy Touch PCB's
input voltage(5V,12V,GND)
OK
Replace PCB
This document can not be used without Samsung's authorization.
- Check Terminal block
voltage(240V).
Reset the circuit braker or
check main power.
Repair the relay or replace
39
OK
Replace PCB
PCB.
Replace or Repair the wiring
Repair Faulty wiring