Software Configuration Instructions - Decatur Electronics SI-2 Technical Manual

System interface
Table of Contents

Advertisement

Software Configuration Instructions

You configure the SI-2 radar device using the SI-2's attached RS232 cable and an IBM-compatible PC with
SI-2 configuration software.
To begin the configuration, you need the following:
SI-2 radar device
SI-2 RS232 programming cable
IBM-compatible PC with Windows
(COM1)
SI-2 Configuration software
12V power supply with a power switch
1. Shut down your computer.
2. Attach the programming cable to the PC's open serial port, using the end of the cable that is without the
red and black twisted-pair cable.
3. Power up the PC.
4. Attach the radar device's 9-pin connector to the other end of the programming cable (the end with the red
and black twisted-pair cable).
5. If the power supply is on, turn it off.
6. Connect the red and black twisted-pair cable to the power supply with the red wire connecting to positive
(+) and the black wire connecting to negative (–).
7. Start the configuration software by double-clicking the Config icon. The Configure Program dialog box
will emerge, as Figure 1 shows.
52
®
OS (95/98, 2000, WinMe and XP) and an open serial port
Figure 1 Click Update in the Configure Program dialog box.