Troubleshooting - Decatur Electronics SI-2 Technical Manual

System interface
Table of Contents

Advertisement

Symptom
Spurious Speeds
No speed reading
when a strong target
is present
No RS-232C
communications
available
Current draw is
much greater than
normal
70

TROUBLESHOOTING

Probable Cause
Misaligned antenna
Misaligned power or
antenna connector
Misaligned
communications
connector or
communications
setting in remote
device is incorrect
Short circuit with
board or antenna
Remedy
1. Align antenna to the target's travel direction.
2. Direct antenna away from moving objects that are
not intended to be targets (including cooling fans
and other rotating objects).
3. Direct the antenna away from electrically noisy
circuitry (such as strong lighting, neon lights, and
exposed clock oscillators) and multiplexed displays.
4. Mount the antenna on a stable surface. If the
mounting moves, the motion is added into the
displayed speed.
See above remedy if you believe the problem is
with the antenna. If you believe there is something
wrong with the power connection, go to the
section on power/communications to see if the
board and connectors are placed correctly. Also,
make sure the processor board is:
1. Mounted in an area that is free from exposure to
liquids.
2. Mounted where interference from other circuits is
minimized.
3. Mounted where the board is not in the beam of the
antenna.
See sections Processor, Power/Communications, and
RS-232C commands to make sure RS-232C
communications are set up correctly.
Disconnect the board and antenna from the power.
Send in the system for repair.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Si-arcade

Table of Contents