Receptacles and Extension Cords

Only use high quality, well-insulated, grounded extension cords in good condition with generator receptacles. Follow each
load manufacturer's power rating recommendation when selecting receptacle and extension cord.
Voltage selector switch---UK
This switch allows the generator to operate in either single voltage 115V or dual voltage (115/230V) mode. When
placed in the 115V position it allows you to receive the full capacity of the generator by duplex (5-20R) at 115V receptacles.
When placed in the 115/230V position, you will only be able to receive half the available watts when using the 115 volt
receptacles and the full available watts when using the 230V 4--prong twist-lock receptacle.
CAUTION!
CAUTION!
Do not connect 3-phase loads to generator.
Extension Cord Selection
Refer to the below table to ensure the extension cord used has the capacity to carry the required load. If the size of the
cable is inadequate it can cause a voltage drop, which can damage the electrical device and cord.
Current
(Amps)
2.5
5
7.5
10
15
20
25
30
Moving the Generator
Disconnect any electronic devices from generator then turn generator off.
Turn fuel valve to the "OFF" position.
Tilt generator until it balances on wheels. Roll machine to desired location.
If the generator must be carried, fold handle to the down position. Never lift or carry generator by its handle.
CAUTION!
Do not move the voltage selector switch while powering electrical devices. Disconnect all
electrical loads before
moving the switch. Failure to disconnect electrical loads could damage the
switch or generator.
Load (Watts)
Maximum Cord Length
230V
#8 Wire
600
X
1200
X
1800
X
2400
X
3800
X
4800
175 ft.
6000
150 ft.
7200
125 ft.
This product is heavy and requires several people to lift. Lift and lower with your legs by bending
at the knees, not your back, to avoid injury.
OPERATION
#10 Wire
#12 Wire
1000 ft.
600 ft.
500 ft.
300 ft.
350 ft.
200 ft.
250 ft.
150 ft.
150 ft.
100 ft.
125 ft.
75 ft.
100 ft.
X
65 ft.
X
19
#14 Wire
#16 Wire
375 ft.
250 ft.
200 ft.
125 ft.
125 ft.
100 ft.
100 ft.
50 ft.
65 ft.
X
X
X
X
X
X
X