Troubleshooting - Bosch TRONIC 4000 C Installation Manual

Electric tankless water heaters
Table of Contents

Advertisement

Installation Manual

12 Troubleshooting

Before calling for service check the troubleshooting list of common issues. This can
save time and cost. If you are unable to resolve a problem contact your installer or
Customer Service for support.
WARNING: ELECTRICAL HAZARD
 Failure to disconnect the power from the water heater
before attempting to install or repair it will result in property
damage, severe personal injury, or death.
Problem
Water Not Hot
Enough
Water Too Hot
Heater Shuts Off
During Use
Water Stops Flowing
Water Temperature Varies from
Hot to Cold During Use
No Hot Water
Leaks
Table 8
2 4 |
Possible Causes
Too much water fl owing through the heater
Temperature setting is too low
Water pressure less than 7 psi (0.5 bar)
Heating element failure
Electrical malfunction
Not enough water fl owing through the heater
Temperature setting is too high
Pre-heated water supply
Power outage or faulty wiring
Blockage in water pipes or hoses
Blockage in cold water inlet
No water supply
Water pressure has dropped below minimum level or fl ow is not
stable.
Power outage or faulty wiring
The fl ow rate needed to activate the heating element
(0.55 gpm) has not been reached.
High Limit Has Been Tripped
Check for leaks at fi ttings
If tank is leaking
Bosch Tronic TR4000C Electric Tankless Water Heaters - BTC 722203301 A (08.2022)
Alternatively, please visit our Service & Support webpage to fi nd FAQs, videos,
service bulletins, and more;
www.boschheatingcooling.com/service
cellphone to scan the code below.
Solution
Reduce the fl ow rate at the faucet or slightly close the shutoff
valve on the unit's incoming water supply line to reduce fl ow
Increase the temperature setting on the unit, see Section 9
Make sure the shutoff valve is fully open and the water supply
line is not blocked
Test element continuity, see Section 12.2.
Contact a qualifi ed electrician or your installer for service
Increase the fl ow rate at the water outlet. If fl ow does not
increase, clean and inspect the water heater inlet fi lter and
faucet aerators/showerheads
Switch to a lower temperature setting, see Section 9
Ensure the heater is connected to a cold water supply
Check the power supply and circuit breaker. If problem
persists, contact a qualifi ed electrician
Ensure the main water shutoff valve is fully open
and there are no obstructions in the water supply line
Remove check valve and inlet fi lter on the cold water inlet and
ensure there are no obstructions. See section 11.3
Ensure the main water shutoff valve is fully open
and there are no obstructions in the water supply line
Increase the fl ow rate from the water supply source. Check for
plumbing crossover or other water supply issues.
Check the power supply and circuit breaker
Ensure shutoff valve to the water heater is fully open. Increase
the fl ow rate from the water supply source
Clean the fi lter screen on the unit's cold water inlet. See section
11.3
Check that the high limit reset buttons are pushed in. Follow
steps to reset the switch in this manual, section 12.1.
Check water fi ttings. Remove front cover and inspect heating
element gasket
Turn off water supply at the shutoff valve. Shut off power to the
water heater, and review warranty to see if heater is still within
warranty period
or use your

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tr4000c-3Tr4000c-6Tr4000c-8Tr4000c-10Tr4000c-13

Table of Contents