Three-Wire Conduit Connection
Loosen the 3 lower terminal screws on the terminal block. Strip wire to expose tip about 3/8''
long.
Insert the center (white/neutral) wire tip through the bottom center terminal block opening. On
certain models, the wire will need to be inserted through the ground strap opening and then into
the bottom center block opening. Insert the two side bare wire tips into the lower left and the lower
right terminal block openings.
Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.) Do not over-tighten the
screws.
Four-Wire Cord Connection
WARNING!
The neutral wire of the supply circuit must be connected to the neutral terminal located
in the lower center of the terminal block. The power leads must be connected to the
lower left and the lower right terminals of the terminal block. The grounding lead must
be connected to the frame of the range with the ground plate and ground screw.
Remove the 3 lower screws from the terminal block. Do not loosen the upper screws.
Remove the ground screw and ground plate and retain them.
Cut the ground strap below the terminal block and discard the lower section.
Insert the ground screw through the power cord ground wire ring through the ground plate and
back into the range frame. Tighten securely, but do not over-tighten (15 to 20 in-lbs).
1. Line 1
2. Ground Strap
3. Neutral terminal
4. Live 2
5. Ground plate
6. Wire tips
A. Black
B. White
C. Red
1. Live 1
2. Ground strap
3. Neutral terminal
4. Live 2
5. Ground plate
6. Ground screw
A. Black
B. White
C. Red
D. Green
EN 9