Insert the 3 terminal screws through each power cord terminal ring and back into the terminal
block. Be certain the white wire is in the center.
Securely tighten each screw (35 to 50 in-lbs).
Four-Wire Conduit Connection
Loosen the 3 lower terminal screws on the terminal block. Strip wire to exposed tip about 3/8''
long.
Remove the ground screw and ground plate and retain them. Cut the ground strap below the
ground block and discard the lower section. Insert the ground screw through the ground plate
(removed earlier) and put it back into the terminal.
Insert the ground wire tip into the ground screw and plate. Tighten securely, but do not over-tighten
(15 to 20 in-lbs).
Insert the center (white/neutral) wire tip through the bottom center terminal block opening. On
certain models, the wire will need to be inserted through the ground strap opening and then into
the bottom center block opening. Insert the two side bare wire tips into the lower left and the lower
right terminal block openings.
Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs). Do not over-tighten the
screws.
NOTE!
ALUMINIUM WIRING: Aluminum building wire may be used, but it must be rated for the correct
amperage and voltage.
Replace the wire cover
Replace the wire cover on the range back by sliding its left edge under the retaining tabs and replace
the screws removed earlier. Make sure that no wires are pinched between the cover and range back.
EN 10
1. Live 1
2. Ground strap
3. Neutral terminal
4. Live 2
5. Ground plate
6. Ground screw
7. Wire tips
A. Black
B. White
C. Red
D. Green