Electrical installation

Range rating, watts
120/240 volts
120/208 volts
3-wire
3-wire
11900 - 14200
8900 - 10800
For power cord installation
Assemble the strain relief in the connection plate hole (1 3/8''). Insert the power cord through the strain
relief and tighten the clamp screws.
NOTE! The power cord must always be installed with strain relief mounted into the connection plate.
NOTE! Terminals on the power cord must be closed-loop or open-end spade lugs.
For conduit installation
Power cord and conduit installation
On the back side of the appliance remove the
metal cover by removing screws using a
screwdriver. Do not discard these screws.
INFORMATION!
NOTE! Power cord and conduit with strain
relief are not included in the appliance. It
must be purchased separately.
Specified rating of
power-supply-cord
kit, amperes
40 or 50 A
1. Conduit connection plate
2. Power cord
3. Strain relief
Remove the conduit connection plate by
removing two screws and rotating it, as shown
below. The conduit hole (1 1/8'') must be used.
Tighten both screws back.
Diameter (inches) of the range
connection opening
Power cord
Conduit
1 3/8''
1 1/8''
EN 7