4) Setting Up Several Cabinets Side by Side
Depending on the temperature and air humidity at the installation site as well as the selected set point
temperature, moisture in the ambient air can condense on the unit surface causing condensation.
If several cabinets are set up side by side, this condensation effect becomes stronger, and a lower air
quantity can circulate between the cabinets. As a result, a minimum distance of 30 to 50 mm must be kept
between the cabinets depending on the temperature and air humidity.
These gaps must not be sealed either at the top or bottom, but can be covered by a stainless-steel panel
from the front for aesthetic purposes. The panel must be removable for cleaning within the gaps.
If it is not possible for air to circulate freely at the bottom, e.g. due to a base installation, then the gaps
cannot be sealed at the front.