Page 1
: HSCFH60WX, HSCFH90WX, HSCFH120WX. All electrical appliances produced by the Company are guaranteed for two years against faulty materials or workmanship. This applies only if the appliance has been used for purposes in accordance with the instructions provided and has not been connected to an unsuitable electricity supply, or subject to misuse, neglect, damage or modified or repaired by any person not authorised by us.
Care must made to the unit, not approved by be taken to allow complete free air movement Heatstore, will void manufacturer’s into the inlet grilles of the unit to ensure correct warranty and potentially create a working operation of the heater.
2.1 Introduction 1. This instruction manual describes the commercial fan heater range from Heatstore. These heaters are robustly designed for use as space heating in large areas. With a maximum heat throw of up to 11m depending on the room temperature...
2. Introduction 2.4 Controllers Controlling heaters using HSTIRFN wireless controller HSTIRFN 30m maximum distance Controlling heaters using HSCFHMC touch screen controller HSCFHMC maximum 8 heaters Optional HSCHES environmental sensor (maximum 2 HSCHES in the system) 3. Intelligent Fan Control 3.1 Automatic speed control The intelligent fan control incorporates one of the latest low energy consumption EC motors.
4. Selecting heater controls 4.1 HSTIRFN Controller 4.3 Heater status indication The heater has to be configured for Light colour Heater status a selected control method at the time Heater is in stand-by mode/ not of installation. Only 1 control method can receiving signal from controller.
Selecting heater controls 4.5 HSCFHMC Controller The heater has to be configured for a selected control method at the time of installation. To control the heater using a HSCFHMC controller the DIP switch 1 located under the electrical connections cover has to be set to ‘0’ as on the picture.
6.2 Electrical connections Attach the heater to the wall bracket. (HSCFH60WX): The heater is suitable for Finally, adjust the direction of the heater to connec-tion to 230-240 Volts single phase 50Hz the desired area and tighten up all clamping supply.
7. Technical Specifications HSCFH60WX HSCFH90WX HSCFH120WX 7.1 General Data Installation height 2.4 - 4 Heat medium Electric heating element Heat output Fan type EC centrifugal fan 133-190 Fan control Electronic fan speed control Heat switching Solid state electronic control Weight...
9. Fault detection / indication 9.1 Fault detection A green LED on the secondary PCBs shows Heaters are equipped with electronic fault that there is power available. The red LED detection. In the event of a fault being will flash one of the sequences as shown in detected, heater will show the nature of the the table below.
10 . BMS Connection MODBUS Protocol 1.1 BMS Connection serial half-duplex interface MODBUS RTU There are 2 ways for connecting heaters to BMS. 9600 baud Using HSCHES and external switch as a 8 bits simple BMS on/off connection 1 start bit Using MODBUS protocol.