ELECTRICAL REQUIREMENTS

CAUTION: Prior to connecting to the
power source, verify the voltage and
phase of the power source to which the unit
will be connected. Make sure that the
power source is identical to the power
requirements identified on the data plate on
the deli case. See chart below for neces-
sary requirements.
Note: Connection of the deli case to the
power source should only be done by a
qualified, licensed electrician.
Refer to the wiring diagram contained in
these directions when connecting to the
power source. The deli case must be ade-
quately and safely grounded. Refer to
local electrical codes and national electrical
code for correct grounding procedures.

ELECTRICAL CHARACTERISTICS

Be sure to check the wiring diagram. It
shows electrical circuits and connections.
When installing or servicing the unit,
always check the dataplate to make cer-
tain proper parts are used and the cor-
rect service rendered. See rated values
DELI CASE MODEL
-
HDM-4
4 ft Complete Deli Case
-
HDM-4
4 ft Countertop Deli Case
-
HDM-4
4 ft Complete Deli Case
-
HDM-4
4 ft Countertop Deli Case
-
HDM-6
6 ft Complete Deli Case
-
HDM-6
6 ft Countertop Deli Case
-
HDM-6
6 ft Complete Deli Case
-
HDM-6
6 ft Countertop Deli Case
-
HDM-6
6 ft Complete Deli Case
-
HDM-6
6 ft Countertop Deli Case
4 - ELECTRICAL REQUIREMENTS
VOLTS
120/240
120/240
120/208
120/208
120/208
120/208
120/240
120/240
120/208
120/240
120/208
120/240
in chart below. DO NOT apply a voltage
to the unit other than that shown on the
dataplate. If in doubt, consult your local
power company.

ELECTRICAL CONNECTIONS

Turn unit OFF and disconnect main
power supply.
A remote circuit breaker or fuse should
be installed in the main power supply
located in a path of exit and clearly iden-
tified.
When installed, the unit must be electri-
cally grounded in accordance with local
codes, or in the absence of local codes,
with the National Electrical Code, ANSI/
NFPA 70, or for Canada, the Canadian
Electrical Code, CSA C22.2, as applica-
ble.
Use copper wire only for connections.
If power run is over 50 feet, use next
larger size wire.
If no component operates, check main
power supply. Be sure main circuit
breaker is ON and main fuses are good.
HZ
WATTS
60
2900
60
2900
60
2900
60
2900
60
4500
60
4500
60
4500
60
4500
60
4500
60
4500
4 - 1
Manual #16287 9/05
AMPS
PLUG CONFIG
15
4-wire grounded
15
4-wire grounded
16
4-wire grounded
16
4-wire grounded
16
5-wire grounded
16
5-wire grounded
15
5-wire grounded
15
5-wire grounded
26
4-wire grounded
24
26
4-wire grounded
24
PHASE
1 PH
1 PH
1 PH
1 PH
3 PH
3 PH
3 PH
3 PH
1 PH
1 PH