HBX SNO-0600 Installation Manual
Hide thumbs Also See for SNO-0600:

Advertisement

Installation Manual
SNO-0600
Version 1.0.0
• Snow Melt Control
SNO-0600
HBX Control Systems Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SNO-0600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HBX SNO-0600

  • Page 1 Installation Manual SNO-0600 Version 1.0.0 • Snow Melt Control SNO-0600 HBX Control Systems Inc.
  • Page 2: Table Of Contents

    Control Systems Inc. H B X S N O - 0 6 0 0 S n o w m e l t C o n t r o l V e r s i o n 1 . 0 . 0 TABLE OF CONTENTS Introduction ....................
  • Page 3: Introduction

    SNOW MELT CONTROL SEE MANUAL FOR RATINGS Optical Snow Melt Sensing The SNO-0600 control works in conjunction with the SNO-0110. The FEATURES snow sensor utilizes optics rather than continuity based on/off sensors typically used by other manufactures. The sensor feedbacks snowfall •...
  • Page 4: Safety Symbols & Warnings

    For more information go to www.P65Warnings.ca.gov. EXTREME HAZARD: This HBX control is a microprocessor based controller and as such is not to be regarded as a safety (limit) control. Please consult and install the heating or cooling appliance in accordance with the manufacturer’s recommendations.
  • Page 5: Technical Data And Dimensions

    V e r s i o n 1 . 0 . 0 TECHNICAL DATA AND DIMENSIONS TECHNICAL DATA AND DIMENSIONS Specifications: SNO-0600 TECHNICAL DATA 4 x thermistor Input (10k Ohm) 2 x Stage Relays 24VAC 2A Max 3 x AUX Relays •...
  • Page 6: Wiring & Installation

    MOUNTING HOLES • Identify the four mounting holes on the SNO-0600, mark on the wall the desired location of mounting • Pre-drill, anchor and fasten four screws for mounting • Hang SNO-0600 and fasten tight to desired locations •...
  • Page 7: Installation

    H B X S N O - 0 6 0 0 S n o w m e l t C o n t r o l V e r s i o n 1 . 0 . 0 SNO-0600 MAIN SCREEN WI-FI – Indicates that the control is connected to a 2.4 GHz Wi-Fi network.
  • Page 8: Main Screen Navigation

    V e r s i o n 1 . 0 . 0 CONTROL STATUS Sync Code SYNC CODE: Sync code of the SNO-0600. SENSOR VOLTAGE: Displays the snow melt optical sensor voltage. This can be used for troubleshooting Sensor Voltage with HBX tech support.
  • Page 9: System Settings

    (2°F to 55°F) Default: 40°F COLD WEATHER SHUTDOWN (CWSD): This is used to set the temperature in which the SNO-0600 will go into CWSD. If the outdoor temperature dips below this temperature, the control will turn OFF. In CWSD the boilers and all pumps will shut off, and slab temperature will not be maintained.
  • Page 10 H B X S N O - 0 6 0 0 S n o w m e l t C o n t r o l V e r s i o n 1 . 0 . 0 SLAB SETUP These setting are used to configure your slab options.
  • Page 11 H B X S N O - 0 6 0 0 S n o w m e l t C o n t r o l V e r s i o n 1 . 0 . 0 SYSTEM SETUP Use Mod Mixing USE MODULATING MIXING: This will enable you to select modulating mixing within your systems setup.
  • Page 12 H B X S N O - 0 6 0 0 S n o w m e l t C o n t r o l V e r s i o n 1 . 0 . 0 WEATHER FORECASTING SETUP These settings are used to configure your snow melt system operation based on your local weather Forecast Settings...
  • Page 13 H B X S N O - 0 6 0 0 S n o w m e l t C o n t r o l V e r s i o n 1 . 0 . 0 PUMP SETUP Pump 1 - The chosen pump type will close the lower Pump 1 contact at 1-2 (PUMP1)when a demand is in place.
  • Page 14 H B X S N O - 0 6 0 0 S n o w m e l t C o n t r o l V e r s i o n 1 . 0 . 0 DEMAND SETUP DEMAND 1: This feature will enable the demand 1 output to close based on the option selected.
  • Page 15 H B X S N O - 0 6 0 0 S n o w m e l t C o n t r o l V e r s i o n 1 . 0 . 0 PERMANENT STANDBY/IDLE PERMANENT STANDBY/IDLE ON: Selecting this option will enable STANDBY/IDLE Permanent Standby/Idle...
  • Page 16 If it displays “Wi-Fi” you may need to open port 1314 on your network router. Wi-Fi SSID Scan – Pressing this will allow the SNO-0600 to actively scan for all available networks that you can choose from, and then you may select the 2.4 GHz network that you wish to connect to.
  • Page 17: Application Drawing

    Under My Buildings will be a list of the available Building locations to choose from. Each building will have the total number of HBX devices linked to that building, name, and address. To add a Building, go to the Plus Symbol on the right of My Buildings and this will go to the Create Building page.
  • Page 18 H B X S N O - 0 6 0 0 S n o w m e l t C o n t r o l V e r s i o n 1 . 0 . 0 Creating & Managing Devices Link Devices will go to a page that will say Scan Device QR Code, Enter Manually and Finished.
  • Page 19 H B X S N O - 0 6 0 0 S n o w m e l t C o n t r o l V e r s i o n 1 . 0 . 0 Controlling a SNO-0600 with the SensorLinx mobile app Status This will display the current operating mode that the snow melt system is in (OFF, STANDBY/IDLE, MELT).
  • Page 20 “Snow Expected” to indicate the days to possible snowfall. Settings: The gear Symbol will allow for changes to the SNO-0600 controller. This will show a more complete list of the settings that are currently set on the SNO-0600. Page 18...
  • Page 21 DEM 2 DEM 1 Optical Sensor Demands Demand In Snow Sensor Sensor 1 Sensor 2 Output Class 2 Circuits SNO-0600 SNOW MELT CONTROL DO NOT CONNECT POWER HERE Class 2 Circuits Boiler Output SNO-0600 Input Power 9 10 POWER Boil 1...
  • Page 22 DEM 1 Slab Optical Sensor Sensor Demands Snow Sensor Demand In Output Sensor 1 Sensor 2 Class 2 Circuits SNO-0600 SNOW MELT CONTROL DO NOT CONNECT POWER HERE Class 2 Circuits Boiler Output SNO-0600 Input Power 9 10 POWER Boil 1...
  • Page 23 H B X S N O - 0 6 0 0 S n o w m e l t C o n t r o l V e r s i o n 1 . 0 . 0 WIRING DIAGRAM 1 GREEN BLACK GREEN...
  • Page 24: Troubleshooting Guides

    DEM 1 DEM 2 Optical Sensor Demands Demand In Snow Sensor Sensor 1 Sensor 2 Output Class 2 Circuits SNO-0600 SNOW MELT CONTROL DO NOT CONNECT POWER HERE Class 2 Circuits Boiler Output SNO-0600 Input Power 9 10 POWER Boil 1...
  • Page 25: Warranty Information

    Control Screen Is Displaying • Do not power down the control. This screen will disappeer after 15- “Control is Bootloading” 30 minutes. For additional assistance with the SNO-0600, please contact our Technical Support Department toll free at: +1 (855) 410-2341 Page 23...
  • Page 26 Make sure System pump is set in PUMP SETUP Boiler is Not Turning On • No Demand present • Check wiring • Check WWSD/CWSD temperatures For additional assistance with the SNO-0600, please contact our Technical Support Department toll free at: +1 (855) 410-2341 Page 24...
  • Page 27 WWSD or CWSD the slab temp will jump by 40F/22C as the control removes the adjustment, and the heater will now slowly cool down which could take up to 1 hour. For additional assistance with the SNO-0600, please contact our Technical Support Department toll free at: +1 (855) 410-2341...
  • Page 28 H B X S N O - 0 6 0 0 S n o w m e l t C o n t r o l V e r s i o n 1 . 0 . 0 TESTING AND TROUBLESHOOTING PROCEDURE SNO-0600/SNO-0110 - TESTING 1. Thermistor Test Resistance table for thermistors (outdoor, system) 2. Snowmelt Sensor Test I.
  • Page 29 Limitation of Liability In no event will HBX be liable for any damages, including loss of data, loss of profits, costs of cover or other incidental, consequential or indirect damages arising out of the installation, maintenance, commissioning, performance, failure or interruption of an HBX product, however caused and on any theory of liability.
  • Page 30 H B X S N O - 0 6 0 0 S n o w m e l t C o n t r o l V e r s i o n 1 . 0 . 0 NOTES Page 28...
  • Page 31 H B X S N O - 0 6 0 0 S n o w m e l t C o n t r o l V e r s i o n 1 . 0 . 0 NOTES Page 29...
  • Page 32 Phone: +1 (403) 720-0029 Fax: +1 (403) 720-0054 Email: info@hbxcontrols.com Web: www.hbxcontrols.com Toll Free Technical Support: +1 (855) 410 2341 HBX Control Systems Inc. 4516 - 112 Avenue SE © HBX Control Systems Inc. 2021 Calgary, AB Canada T2C 2K2...

Table of Contents