50-Pin Connector; Backup Battery; Removal/Installation Of Flexible Card Wires - Sony BETACAM SX DNV-5 Maintenance Manual

Hide thumbs Also See for BETACAM SX DNV-5:
Table of Contents

Advertisement

1-13. 50-pin Connector

1-14. Backup Battery

1-15. Removal/Installation of Flexible Card Wires

1-13. 50-pin Connector
The position of the 50-pin connector on the VTR is
previously calibrated at the factory with a special tool. If
this position is incorrect, the VTR connector cannot make
positive contact with the camera or so. Therefore, do not
remove the fixing screws of the V connector holder and
50-pin connector except in an emergency.
. When you check the 50-pin connector portion, remove
the C holder cap as shown in the figure.
. If the lead wire is happened to be open at the 50-pin
connector portion, solder the lead wire and contact.
C holder cap
50-pin connector
(_) 2 mm or 3 mm screwdriver
. If the connector indicates a poor contact with the plug,
remove the contact as shown in the figure and replace it
with a new one.
Never loosen these screws.
Contact
Lead wire
Push the play with
this steel rod.
0.6 mm dia. steel rod
(Replacement procedure)
1-30
1-14. Backup Battery
The lithium battery for data backup operation is mounted
on the TC-80 board. Replace the lithium battery every five
years. For more details of the replacement, refer to "1-3.
Lithium Battery Replacement" of the Maintenance Manual
Part 2 Vol-1.
1-15. Removal/Installation of Flexible
Card Wires
m
. Be sure to turn off the power, then pull out the power
cord and/or battery before performing the following
procedure. If not, damage to internal circuit may result.
. Two 30-pin flexible card wires are used between the
MB-627 and the TC-80 boards. Be careful not to break
these flexible card wires. This shortens the wire life.
Removal
Slide portions A in the direction indicated by the arrow,
unlock it, then pull out the flexible card wire.
Portions A
Flexible card wire
Installation
1. Check that the conductive surface of the flexible card
wire is not soiled with dust.
2. Slide portions A in the direction indicated by the arrow
and insert the flexible card wire tightly into each
connector with the conductive surface of these wires
put down.
n
Be careful not to insert the flexible card wires oblique-
ly.
3. Slide portions A in the reverse direction of the arrow
and lock each connector.