Continuous Tightening Tool - Preparation
Air Preparation
To perform correctly, this pneumatic tool requires a continuous
flow of clean, dry and lubricated air at a suitable pressure.
Air Flow
Air motors inevitably need high flow requirements and this
should be taken into consideration before set up.
Smart
Band 19mm (¾˝) Hybrid & Compact and Smart
®
20mm (¾˝) tools – Requires a continuous air flow of 935 l/min
(33 CFM).
Note: A pneumatic supply hose with internal bore of at least
10mm (⅜˝) must be used to allow an adequate volume of
compressed air to supply the tool.
PRESSURE REGULATOR
AIR FILTER
KNOB FOR ADJUSTING PRESSURE
All tools are supplied with a 5m supply hose.
w w w.h clfaste ne rs . com
LUBRICATED AIR INPUT
LIFTING EYES
BAND EXIT SLOT
Tie
®
KNOB FOR VERIFYING AND
ADJUSTING OIL DROPS
AIR ISOLATION VALVE
AIR LUBRICATOR
TRIGGER
Smart
Band 32mm (1¼˝) Hybrid & Compact and Smart
®
32mm (1¼˝) tools – Requires a continuous air flow of
1,000 l/min (35 CFM).
Note: A pneumatic supply hose with internal bore of at least
10mm (⅜˝) must be used to allow an adequate volume of
compressed air to supply the tool.
IMPORTANT – THE TOOL WILL NOT OPERATE TO
SPECIFICATION UNLESS THE MINIMUM AIRFLOW AND AIR
REGULATION REQUIREMENTS HAVE BEEN MET.
Air Filter
For best results, use a 50 micron filter or better.
Pressure Regulator
A pressure regulator is essential for controlling the performance
of the tool and should be mounted as close to the tool as
possible, preferably within 5m (15ft). The maximum allowable
static pressure (tool not running) for the tool is 0.7 MPa (7.0
bar). The recommended pressures (see section 2.2) are given as
Dynamic pressures (when the tool is running).
Air Lubricator
*IMPORTANT* – Risk of seizure if not adhered to.
The tool should be lubricated with 6 to 8 drops of oil per minute
of continuous use, in order to maintain the life of the air motor
and prevent seizing. Lubricators should always be mounted as
close to the tool as possible, preferably within 3m (10ft). Always
mount the lubricator at least as high, or preferably higher than
the tool. HCL recommend allowing 100ml/1000 strap fittings
FOR MORE INFORMATION REFER TO THE PNEUMATIC
NUTRUNNER TOOL MANUAL
2.1