Fan - Bentone BG 400 M Translation Of The Original Instructions

Table of Contents

Advertisement

7.6

Fan

1.
Disconnect the main power and shut off the fuel supply.
!
Before obtaining access to electrical and fuel line components
all supply circuits must be disconnected.
Detach the electrical panel (Y).
2.
Loosen the motor electrical connection and screws (X) enough to turn
3.
and lift out the motor.
4.
Check the fan wheel attachment and any skew, replace if damaged.
5.
Clean or replace the fan wheel.
6.
Refi t the parts.
7.
Switch on the main power and open the fuel supply.
Start burner and check/adjust combustion.
8.
When servicing/replacing components that aff ect combustion,
!
fl ue gas analysis and soot test must be carried out following
installation.
30
Bentone
X
Y
172 625 09