Problem
The Timed on/off
function does not
operate.
The indoor unit
display blinks
continuously.
Air does not come
out of the air
conditioner.
DB68-09343A-00_IBIM_PAC 미라지 이집트파키스탄_IQ_EN.indd 31
• Check whether you pressed the
after setting the on/off time. Set the on/off time.
• Check whether
,
Make sure that the power and communication cables are connected
correctly between the indoor and outdoor units, and then restart the air
conditioner. If the error is still displayed, contact a service centre.
• Check whether the following errors are displayed on the indoor unit display:
,
,
,
,
,
,
,
,
• In the Cool mode, air does not come out if the set temperature is higher
than the current temperature.
• Cooling does not operate in the Fan mode. Select the Cool, Auto, or Dry mode.
• Check whether the air filter is blocked with dirt. A dusty filter may
decrease the cooling efficiencies. Clean the air filter frequently.
• If a cover is on the outdoor unit or any obstacle is present near the outdoor
unit, remove them.
• Install the outdoor unit in a well-ventilated place. Avoid places exposed to
direct sunlight or close to a heating appliance.
• Place a sunscreen over the outdoor unit to protect it from direct sunlight.
• If the indoor unit is installed in a place exposed to direct sunlight, pull the
curtains on the windows.
• Close the windows and doors to maximize the cooling efficiencies.
• If the Cool mode is stopped and then started immediately, cool air comes
out after about 3 minutes to protect the compressor of the outdoor unit.
• If the refrigerant pipe is too long, the cooling efficiencies may be
decreased. Avoid exceeding the maximum pipe length.
Solution
(SET) button on the remote control
is displayed on the indoor unit display.
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
31
English
2020-07-28 오전 11:08:49