CASTING INSTALL
Slide the casting partially onto the
4
stanchion assembly, such that the
air spring and rebound end fittings
are not yet in contact with the
casting threads. Take care during
installation to not fold over fork
seal lips on the stanchions.
Insert 7cc of semi-bath into each
5
casting leg. Once the semi-bath is
in the legs, slide the casting the
rest of the way onto the stanchion
assembly.
Using an 8mm Hex wrench and
6
torque wrench, tighten the rebound
damper rod to 30–40 in lb [3.4–4.5
N m] by turning them counter-
clockwise. Do not overtighten, as
doing so can damage the end of
the rods.