ADTRAN ATLAS User Manual page 56

Frame relay
Table of Contents

Advertisement

Chapter 5. Connecting Packet Endpoints
5-4
O
C
ID
UTGOING
ALLER
Write security: 3; Read security: 5
Defines the presentation of the calling party number for this endpoint.
S
ID
OURCE
Write security: 3; Read security: 5
Used to simplify the creation of a D
rion for switching calls to a certain endpoint is a function of which endpoint
originated the call. For further details, see the ATLAS 800
R
I
C
OUTE
NCOMING
ALL
Write security: 3; Read security: 5
Used to define the method which incoming calls are associated to the
packet endpoints. This item can have three options:
U
I
N
SING
NCOMING
UM
Endpoint selection based on the incoming number.
U
C
P
SING
ALLING
ARTY
Selection based on the Call ID as presented by the calling party. If this
option is selected, the C
the interface configuration. This number allows you to configure the
calling part number used to select this packet endpoint.
U
DBU H
SING
ANDSHAKE
Selection based on a proprietary protocol. This option is only available
to packet endpoints with backup sublinks. DBU H
to interoperate with ADTRAN IQ and Express family products. It
enables the association of incoming calls with packet endpoints in cases
where there is a single call-in number (hunt group) and no Caller ID
information available.
S
DBU H
UPPORT
ANDSHAKE
Write security: 3; Read security: 5
This option is only available when the packet endpoint selected in the
/PEP field has backup sublinks. S
P
ORT
disables the generation and acceptance of ADTRAN frame relay handshake
upon connection. If the endpoint is configured to route incoming calls
based on the handshake information, this option is automatically enabled.
If another call routing method is in effect, however, this option can be
enabled to support the use of handshake information at the far end of the
link.
M
DS0'
IN
S
Write security: 3; Read security: 5
Set this to 1 for typical single-call connections. Setting this greater than 1
will restrict connections to endpoints supporting aggregation (e.g.,
BONDING) of the specified number of DS0s.
M
DS0'
AX
S
Write security: 3; Read security: 5
Set this to 1 for typical single-call connections. Setting this greater than 1
will accommodate connections to endpoints supporting aggregation (e.g.
BONDING) of up to the specified number of DS0s. This also sets the num-
ber of DS0s presented in the negotiation of outgoing aggregate calls.
ATLAS Frame Relay User Manual
P
in applications where the crite-
IAL
LAN
N
UM
P
N
field is made available to
ALL
ARTY
UMBER
DBU H
UPPORT
PLUS
User Manual.
is required
ANDSHAKE
enables/
ANDSHAKE
61200263L1-1.1