Installation Instructions

Installation Clearance Requirements

When installing the kegerator under a counter, follow the recommended spacing dimensions shown.
For proper clearance of the electrical plug, allow at least 1" of clearance at the back as shown in
the diagram.
An installation next to a wall will require a minimum 2-1/4" door clearance to accommodate the
Zephyr handle.
The cabinet should allow at least 24" for the width and 34" for the height to accommodate the
kegerator.
The power cable is located on the back right of the unit and has a length of 78-11/16" to
accommodate multiple outlet locations.
Once you are ready to install the unit, you must adjust the feet to level the kegerator.
This unit can be fully built-in to cabinetry and does not require any additional clearances besides
what is referenced below.
The installation should allow the unit to be pulled forward for servicing, if necessary.
Install the included Zephyr Kegerator built-in kit by following the instructions on page 25.
16
PRKB24C01AG & PRKB24C01AS-OD Use, Care, and Installation Guide
P R E S R V ™
K E G E R ATO R &
B E V E R A G E C O O L E R
I N D O O R & O U T D O O R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Presrv PRKB24C01AG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Presrv prkb24c01as-od

Table of Contents