Summary of Contents for Zephyr Presrv PRB24C01AG-ADA
Page 1
WWW.ZEPHYRONLINE.COM PRB24C01AG-ADA Presrv Single Zone Beverage Cooler EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation APR21.0101...
Page 2
P R E S R V ™ B E V E R A G E C O O L E R S I N G L E ZO N E PRB24C01AG-ADA Use, Care, and Installation Guide...
Installation Clearance Requirements .............16 Carbon Filter ..................17 Installing the Handle ................17 Reversing the Door Swing of Your Appliance ........18 Installing the Zephyr Logo After Reversing the Door ......19 Removing the Wooden Shelves ............19 Removing the Glass Shelves .............. 20 Operating Your Appliance ..............21-23 Using the Control Panel ..............21...
P R E S R V ™ Safety Information B E V E R A G E C O O L E R S I N G L E Z O N E Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance.
Safety Information ZEPHYRONLINE.COM For your safety, read all instructions carefully before operating the appliance. General Safety DANGER When using an electrical appliance, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons. WARNING To reduce the risk of fire, electric shock or personal injury, unplug or disconnect the appliance from the power supply before...
Page 6
P R E S R V ™ Safety Information B E V E R A G E C O O L E R S I N G L E Z O N E For your safety, read all instructions carefully before operating the appliance. To disconnect the appliance, grip the plug and pull it from the wall outlet.
Page 7
Safety Information ZEPHYRONLINE.COM For your safety, read all instructions carefully before operating the appliance. WARNING Never operate any other electrical appliance inside this appliance. Never attempt to repair or replace any part of your appliance unless it is specifically recommended in this manual. All other servicing should be referred to a qualified technician. Replace all access panels before operating.
P R E S R V ™ Safety Information B E V E R A G E C O O L E R S I N G L E Z O N E For your safety, read all instructions carefully before operating the appliance. Save These Instructions If you are experiencing problems, check the Troubleshooting Guide at the back of this manual.
Safety Information ZEPHYRONLINE.COM For your safety, read all instructions carefully before operating the appliance. Before Using Your Appliance Remove all exterior and interior packing. Before connecting the appliance to the power source, let it stand upright for approximately 2 hours. This will reduce the possibility of a malfunction in the cooling system caused by handling during transportation.
P R E S R V ™ Safety Information B E V E R A G E C O O L E R S I N G L E Z O N E For your safety, read all instructions carefully before operating the appliance. The appliance must be installed to all electrical connections in accordance with state and local codes.
Safety Information ZEPHYRONLINE.COM For your safety, read all instructions carefully before operating the appliance. Electrical Connection Check that the voltage marked on the product corresponds with your supply voltage. WARNING Improper use of the grounded plug can result in the risk of electrical shock.
C O O L E R S I N G L E Z O N E Thank you for purchasing your Zephyr beverage cooler. Zephyr is dedicated to developing products that will enhance your lifestyle with superior quality and distinctive features. Please visit www.zephyronline.com for more information on your product and other Zephyr products.
Decorative nails (2 grey, 3 black) Child safety lock keys Zephyr logo Zephyr Logo Application Template for ADA models 1.Place template on front of door and fold it over the top of the door along the dashed line. Logo positioning tool 2.Align the two dots on the template with the holes...
P R E S R V ™ B E V E R A G E C O O L E R S I N G L E Z O N E Product Summary This appliance requires a standard 115/120 Volt AC~60Hz electrical ground outlet. DESCRIPTION OF PRODUCT Presrv Single Zone Beverage Cooler MODEL...
ZEPHYRONLINE.COM Seamless Stainless Door Control Panel Carbon Filter Internal Fan Roll-out Shelf Door Handle Retractable Glass Shelf Retractable Glass Shelf Sensor Child Safety Lock Front Vent Leveling Legs Dimensions ” ” ” ” Top View Side View Max 135° PRB24C01AG-ADA Use, Care, and Installation Guide...
An installation next to a wall will require a minimum 2-1/4” door clearance to accommodate the Zephyr handle. The cabinet should allow at least 24” for the width and 33” for the height to accommodate the beverage cooler.
1. Push aside the door gasket on the side you wish to install the handle. Under the gasket you will see two designated holes for handle installation and pre-installed screws. 2. Install the handle tightly as shown with two screws, lock washers and flat washers pre-installed. Zephyr Presrv Contemporary Handles Part #: PRHAN-C101 Color: Stainless Steel...
(5), unscrew 2 screws and remove the child safety lock (6), and remove and discard the Zephyr logo (7). Then, install the door magnet, child safety lock, and new door stopper (8) on the opposite side of the door frame. Rotate the...
Logo Positioning Tool 1. Clean the top surface of the door so the adhesive from the Zephyr logo will adhere to the door. 2. Place the logo positioning tool between the two holes on top of the door and align it.
P R E S R V ™ Installation Instructions B E V E R A G E C O O L E R S I N G L E Z O N E Removing the Glass Shelves 1. Open the door completely unload any content within the cooler.
Operating Your Appliance ZEPHYRONLINE.COM If the unit is unplugged, power lost, or turned off, you must wait 3 to 5 minutes before restarting the unit. If you attempt to restart before this time delay, the appliance may not start and will not keep the last set temperature.
P R E S R V ™ Operating Your Appliance B E V E R A G E C O O L E R S I N G L E Z O N E Internal Light This refrigerator is equipped with side internal lights that can be set to Cloud White, Deep Blue or Amber.
Operating Your Appliance ZEPHYRONLINE.COM Demonstration Mode In this mode, the compressor and fans never turn on but all other functions remain enabled. When in Demonstration Mode, the “R” indicator light will slowly blink indicating it is in Demonstration Mode. To enable or disable Demonstration mode, hold Power Button and tap Decrease Temperature Button twice.
P R E S R V ™ Care and Maintenance B E V E R A G E C O O L E R S I N G L E Z O N E Normal Sounds Your new beverage cooler may make sounds that are not familiar to you. Most of the new sounds are normal.
Care and Maintenance ZEPHYRONLINE.COM Power Failure Most power failures are corrected within a few hours and should not affect the temperature of your appliance if you minimize the number of times the door is opened. If the power is going to be off for a longer period of time, you need to take the proper steps to protect your contents.
P R E S R V ™ Troubleshooting B E V E R A G E C O O L E R S I N G L E Z O N E Possible Problem Possible Cause Solutions Ensure the appliance is plugged in Not plugged in.
Page 27
Troubleshooting ZEPHYRONLINE.COM Possible Problem Possible Cause Solutions The unit uses an ‘auto-defrost’ The environment is too humid. system, under certain conditions, The ambient temperature is too low. manual defrosting may be required. If frost builds up, you Frost is forming in the can try running the refrigerator appliance.
Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows:...
Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.8368 PRB24C01AG-ADA Use, Care, and Installation Guide...
Page 31
WWW.ZEPHYRONLINE.COM PRB24C01AG-ADA Presrv refroidisseur de boissons à zone unique EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation APR21.0101...
Page 32
P R E S R V ™ R E F R O I D I S S E U R D E B O I S S O N S ZO N E U N I Q U E PRB24C01AG-ADA Guide d’utilisation, d’entretien et d’installation...
Page 33
Installation de la poignée ................17 Inverser l’ouverture de la porte de votre appareil ......... 18 Installation du logo Zephyr après avoir renversé la porte ......19 Retrait des étagères en bois ................ 19 Retrait des clayettes en verre............... 20 Fonctionnement de votre appareil ..............21-23...
Consignes de sécurité ZEPHYRONLINE.COM Pour votre sécurité, lisez toutes les instructions avec soin avant de faire fonctionner l’appareil. Sécurité générale DANGER Lors de l’utilisation d’un électroménager électrique, vous devriez toujours prendre des précautions de base pour réduire les risques d’incendie, de décharge électrique et de lésion corporelle.
Page 36
P R E S R V ™ Consignes de sécurité R E F R O I D I S S E U R D E B O I S S O N S ZO N E U N I Q U E Pour votre sécurité, lisez toutes les instructions avec soin avant de faire fonctionner l’appareil.
Page 37
Consignes de sécurité ZEPHYRONLINE.COM Pour votre sécurité, lisez toutes les instructions avec soin avant de faire fonctionner l’appareil. Assurez-vous que les orifices d’aération de l’appareil et les évents se trouvant à proximité de celui- ci ne sont jamais couverts ou bloqués. Nous n’assumons aucune responsabilité...
P R E S R V ™ Consignes de sécurité R E F R O I D I S S E U R D E B O I S S O N S ZO N E U N I Q U E Pour votre sécurité, lisez toutes les instructions avec soin avant de faire fonctionner l’appareil.
Consignes de sécurité ZEPHYRONLINE.COM Pour votre sécurité, lisez toutes les instructions avec soin avant de faire fonctionner l’appareil. Avant d’utiliser votre appareil Enlevez tout l’emballage intérieur et extérieur. Avant de brancher l’appareil à l’alimentation électrique, laissez-le en position verticale pendant environ deux heures.
P R E S R V ™ Consignes de sécurité R E F R O I D I S S E U R D E B O I S S O N S ZO N E U N I Q U E Pour votre sécurité, lisez toutes les instructions avec soin avant de faire fonctionner l’appareil.
Consignes de sécurité ZEPHYRONLINE.COM Pour votre sécurité, lisez toutes les instructions avec soin avant de faire fonctionner l’appareil. Raccordement électrique Assurez-vous que la tension indiquée sur le produit correspond à la tension d’alimentation. AVERTISSEMENT L’utilisation incorrecte de la prise de mise à la terre peut entraîner des risques de décharge électrique.
ZO N E U N I Q U E Merci de vous être procuré un refroidisseur de boissons Zephyr. Zephyr se spécialise dans l’élaboration de produits de qualité supérieure dotés de fonctionnalités distinctives qui améliorent votre style de vie. Veuillez visiter le www.zephyronline.com pour obtenir de plus amples renseignements sur votre appareil et sur d’autres produits Zephyr.
Clés de verrouillage de sécurité pour enfants Logo Zephyr Zephyr Logo Application Template for ADA models 1.Place template on front of door and fold it over the Outil de positionnement de logo top of the door along the dashed line.
ZEPHYRONLINE.COM Porte en acier inoxydable Tableaux de commande Filtre à charbon Ventilateur interne Tablette coulissante Poignée de porte Tablette en verre rétractable Tablette en verre rétractable Capteur Verrou de sécurité Évent avant pour enfants Pattes de nivelage Dimensions Vue en plan Vue de côté...
Une installation à côté d’un mur nécessitera un dégagement de porte minimum de 2-1/4 po pour accueillir la poignée Zephyr. L’armoire doit permettre au moins 24 po pour la largeur et 33 po pour la hauteur pour accueillir le refroidisseur de boisson.
2. Fixez fermement la poignée en place comme indiqué en utilisant les deux vis, les rondelles d’arrêt et les rondelles plates préinstallées. Zephyr Presrv poignées contemporaines Partie #: PRHAN-C101 Couleur: acier inoxydable Partie #: PRHAN-C102 Couleur: or brossé...
(5), dévissez 2 vis et retirez la sécurité enfants (6), puis retirez et jetez le logo Zephyr (7). Ensuite, installez l’aimant de la porte, la sécurité enfants et la nouvelle butée de porte (8) sur le côté opposé...
2. Placez l’outil de positionnement de logo entre les deux trous sur le dessus de la porte et alignez-le. 3. Retirez le film sous le logo et placez le logo Zephyr sur le dessus de la porte. Appuyez fermement sur le logo, en vous assurant qu’il adhère.
Page 50
P R E S R V ™ Instructions d’installation R E F R O I D I S S E U R D E B O I S S O N S ZO N E U N I Q U E Retrait des étagères en verre 1.
Fonctionnement de votre appareil ZEPHYRONLINE.COM Si l’unité est débranchée, coupée de courant ou éteinte, vous devez attendre 3 à 5 minutes avant de redémarrer l’unité. Si vous essayez de redémarrer avant ce délai, l’appareil risque de ne pas démarrer et de ne pas conserver la dernière température réglée. Utilisation du tableau commande La température de ce refroidisseur de boissons peut être réglée entre 34°F et 50°F.
P R E S R V ™ Fonctionnement de votre appareil R E F R O I D I S S E U R D E B O I S S O N S ZO N E U N I Q U E Éclairage intérieur Le refroidisseur est équipé...
Fonctionnement de votre appareil ZEPHYRONLINE.COM Mode vitrine Avec ce mode, le compresseur et les ventilateurs ne s’allument jamais, mais toutes les autres fonctions demeurent actives.Lors de l’utilisation du mode vitrine, un témoin lumineux R clignote lentement sur l’écran d’affichage. Pour activer ou désactiver le mode vitrine, appuyez sur le bouton d’alimentation en appuyant simultanément deux fois sur le bouton de diminution de la température.
P R E S R V ™ Entretien R E F R O I D I S S E U R D E B O I S S O N S ZO N E U N I Q U E Bruits normaux Votre refroidisseur de boissons peut émettre des bruits auxquels vous n’êtes pas habitués.
Entretien ZEPHYRONLINE.COM Panne d’électricité Most power failures are corrected within a few hours and should not affect the temperature of your appliance if you minimize the number of times the door is opened. If the power is going to be off for a longer period of time, you need to take the proper steps to protect your contents.
P R E S R V ™ Dépannage R E F R O I D I S S E U R D E B O I S S O N S ZO N E U N I Q U E Problème possible Cause possible Solutions...
Page 57
Dépannage ZEPHYRONLINE.COM Problème possible Cause possible Solutions Contactez votre électricien local Le corps de l'appareil L'unité n'est pas correctement mise à la pour tester votre système de mise à est électrifié. terre. la terre électrique. Bien que l’appareil utilise un L’environnement est humide.
P R E S R V ™ Remarques R E F R O I D I S S E U R D E B O I S S O N S ZO N E U N I Q U E PRB24C01AG-ADA Guide d’utilisation, d’entretien et d’installation...
Zephyr Ventilation, LLC (appelé aux présentes « nous ») garantit au premier acheteur (appelé aux présentes « vous ») des produits Zephyr (les « produits ») que ces produits sont exempts de défauts de matériau et de fabrication, comme suit : Garantie limitée de cinq ans sur le compresseur : Pour une...
D E B O I S S O N S ZO N E U N I Q U E Nous vous félicitons d’avoir acheté une produit Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle produit au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à...
Need help?
Do you have a question about the Presrv PRB24C01AG-ADA and is the answer not in the manual?
Questions and answers