Download Print this page

Remote Switching Specifications - Condari QASAIR H Series Installation & User's Instructions

Advertisement

1. Wiring to the appliance must comply with State and local regulations.
2. Switching is not provided with this unit.
3. You may use any approved switching to connect the rangehood (e.g. Clipsal switches).
4. All fans must be controlled by at least one ON/OFF and one HI/LO switch.
5. Please refer to Wiring Diagram below for detailed wiring information.
WIRING DIAGRAM
JUNCTION BOXES INSIDE RANGEHOOD
FAN 1
JUNCTION
BOX
NOTE: This diagram is for reference only. A qualified elecrician must connect remote
switching to rangehood.
Reflected in this drawing is the most common method of connecting the rangehood.
Be aware that Active voltage must NOT be applied to both the 'Black-High' and
'Brown-Low' wires at the same time. This will cause the fan to fail.
30

REMOTE SWITCHING SPECIFICATIONS

3 FAN (no lights)
FAN 2 & 3
JUNCTION
BOX
CONDARI PTY LTD
8 Argent Place, Ringwood VIC 3134
Ph: (03) 9873 5877 / Fx: (03) 9873 5748
For further information, please contact Condari Pty Ltd
phone: 03 9482 7088 fax: 03 9482 7011
www.condari.com.au
E
CIRCUIT DIAGRAM
ALFRESCO REMOTE SWITCH 3 FAN
NOTES:-
1. ALL FANS MUST BE CONTROLLED BY
AT LEAST ONE ON/OFF AND ONE
HI/LO SWITCH WIRED IN SERIES TO
ENSURE ACTIVE VOLTAGE FOR HIGH
AND LOW IS NOT APPLIED TO THE
FAN AT THE SAME TIME.
2. THE WIRING FOR THE FANS -
LOW SPEED - BROWN
HIGH SPEED - BLACK
NEUTRAL
- BLUE
3. EARTH TERMINAL ADJACENT
JUNCTION BOXES
27/02/2020
S. STOPHER
DATE
DESIGNER
M. Malesevic
CHECKED
REVISION
DRAWING NUMBER
REM SW 3 FAN BBQ
Qasair Rangehoods Installation Instructions
B

Advertisement

loading