Condari QASAIR NDCH Installation & User's Instructions

Qasair series undercupboard

Advertisement

UNDERCUPBOARD
INSTALLATION & USER
INSTRUCTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QASAIR NDCH and is the answer not in the manual?

Questions and answers

Summary of Contents for Condari QASAIR NDCH

  • Page 1 UNDERCUPBOARD INSTALLATION & USER INSTRUCTIONS...
  • Page 2 Qasair Rangehoods Installation Instructions...
  • Page 3 Important Information Cutout Dimensions Duct Direction Change Instructions Instructions for Models MT / MC Instructions for Models Instructions for Models CON / NDCH / LIS / ETN Instructions for Models Instructions for Models WES / EAS Remote Switching Specifications Ducting Pieces Installation Ideas Operation Details, Rangehood Cleaning, Filter Cleaning Appliance Guarantee...
  • Page 4: Important Information

    Do not reduce the duct size or have sharp bends. Enlarge the duct size if the duct is to run 6 metres or longer. Advice from CONDARI is available to ensure optimum performance.
  • Page 5 5. NOTE: CONDARI recommend an air movement of between 1000 to 1400 cubic metres per hour over an indoor barbecue, depending on the length of the duct run. Ensure a twin motor unit is installed over indoor barbecues for optimum results.
  • Page 6 INSTALLATION INSTRUCTIONS EXECUTIVE / FLINDERS RANGE CUTOUT DIMENSIONS PROUD MOUNT FLUSH MOUNT MODEL HOOD SIZE BASE SIZE CUT OUT DIMENSION CUT OUT DIMENSION CON 60L 243 x 580 280 x 600 258 x 585 280 x 600 CON 80L 243 x 780 280 x 800 258 x 785 280 x 800...
  • Page 7 DUCT DIRECTION CHANGE INSTRUCTIONS Before installing your rangehood check whether it has the fan mounted for back or top ducting. For top ducting, the unit will have the air outlet at the top, and for back ducting, the unit will have the air outlet at the back.
  • Page 8 Installation must be carried out by the procedure outlined. INSTALLATION INSTRUCTIONS Failure to do so may void the guarantee. Electrical: Wiring to the appliance must comply with State and local Regulations. • MT Connection to be carried out by a registered electrician. •...
  • Page 9 Cool Cool (H =) Maximum Height Nightlight (H =)  PowderKote Light Qty Available All-thread Light Centres 320mm Fixing Centres Filter Qty Corner Type Square Square Condari Pty Ltd. Page 1 of 1 Version: B 03/12/2014F Qasair Rangehoods Installation Instructions...
  • Page 10 LED Light Cool (H =) Maximum Height Nightlight (H =)  PowderKote Light Qty Available All-thread Light Centres 320mm Fixing Centres Filter Qty Corner Type Square Condari Pty Ltd. Page 1 of 1 Version: B 03/12/2014 Qasair Rangehoods Installation Instructions...
  • Page 11 Installation must be carried out by the procedure outlined. INSTALLATION INSTRUCTIONS Failure to do so may void the guarantee. Electrical: Wiring to the appliance must comply with State and local Regulations. • FA Connection to be carried out by a registered electrician. 1.
  • Page 12 (H =) Maximum Height Nightlight (H =)  PowderKote Light Qty Available All-thread Light Centres Centre 350mm 350mm Fixing Centres Filter Qty Corner Type Square Square Square Condari Pty Ltd. Page 1 of 1 Version: B 03/12/2014F Qasair Rangehoods Installation Instructions...
  • Page 13 Installation must be carried out by the procedure outlined. INSTALLATION INSTRUCTIONS Failure to do so may void the guarantee. Electrical: Wiring to the appliance must comply with State and local Regulations. • CON Connection to be carried out by a registered electrician. •...
  • Page 14 (H =) Maximum Height Nightlight (H =)  PowderKote Light Qty Available All-thread Light Centres Centre 379mm 379mm Fixing Centres Filter Qty Corner Type Square Square Square Condari Pty Ltd. Page 1 of 1 Version: A 01/07/2014 Qasair Rangehoods Installation Instructions...
  • Page 15 Cool (H =) Maximum Height Nightlight (H =) PowderKote  Light Qty Available All-thread Light Centres 770mm 770mm Fixing Centres Filter Qty Corner Type Square Square Condari Pty Ltd. Page 1 of 2 Version: B 19/12/2014F Qasair Rangehoods Installation Instructions...
  • Page 16 Cool (H =) Maximum Height Nightlight (H =) PowderKote  Light Qty Available All-thread Light Centres 860mm 1060mm Fixing Centres Filter Qty Corner Type Square Square Condari Pty Ltd. Page 2 of 2 Version: B 19/12/2014F Qasair Rangehoods Installation Instructions...
  • Page 17 (H =) Maximum Height Nightlight (H =)  PowderKote Light Qty Available All-thread Light Centres Centre 380mm 380mm Fixing Centres Filter Qty Corner Type Square Square Square Condari Pty Ltd. Page 1 of 3 Version: B 03/12/2014F Qasair Rangehoods Installation Instructions...
  • Page 18 Cool (H =) Maximum Height Nightlight (H =) PowderKote  Light Qty Available All-thread Light Centres 480mm 424mm Fixing Centres Filter Qty Corner Type Square Square Condari Pty Ltd. Page 2 of 3 Version: B 03/12/2014F Qasair Rangehoods Installation Instructions...
  • Page 19 (H =) Maximum Height Nightlight (H =)  PowderKote Light Qty Available All-thread Light Centres 580mm 580mm 452mm Fixing Centres Filter Qty Corner Type Square Square Square Condari Pty Ltd. Page 3 of 3 Version: B 03/12/2014F Qasair Rangehoods Installation Instructions...
  • Page 20 Cool (H =) Maximum Height Nightlight (H =)  PowderKote Light Qty Available All-thread Light Centres 520mm 800mm Fixing Centres Filter Qty Corner Type Square Square Condari Pty Ltd. Page 1 of 2 Version: C 2/6/2016F Qasair Rangehoods Installation Instructions...
  • Page 21 Cool (H =) Maximum Height Nightlight (H =) PowderKote  Light Qty Available All-thread Light Centres 800mm 1060mm Fixing Centres Filter Qty Corner Type Square Square Condari Pty Ltd. Page 2 of 2 Version: C 2/6/2016F Qasair Rangehoods Installation Instructions...
  • Page 22 INSTALLATION INSTRUCTIONS Installation must be carried out by the procedure outlined. Failure to do so may void the guarantee. Electrical: Wiring to the appliance must comply with State and local Regulations. • WCV Connection to be carried out by a registered electrician. All the rangehoods are supplied as Top ducted and can be Side or Back ducted through separate ducting pieces.
  • Page 23 Cool (H =) Maximum Height Nightlight (H =) PowderKote  Light Qty Available All-thread Light Centres 580mm 580mm Fixing Centres Filter Qty Corner Type Square Square Condari Pty Ltd. Page 1 of 3 Version: A 13/11/2014F Qasair Rangehoods Installation Instructions...
  • Page 24 Cool (H =) Maximum Height Nightlight (H =)  PowderKote Light Qty Available All-thread Light Centres 872mm 816mm Fixing Centres Filter Qty Corner Type Square Square Condari Pty Ltd. Page 2 of 3 Version: A 13/11/2014F Qasair Rangehoods Installation Instructions...
  • Page 25 1 1 0 1 1 0 1 5 0 1 3 8 SIDE DUCTED PIECES WCV S2 WCV S3 W C V S 3 T Ducted Pieces Condari Pty Ltd. Version: A 13/11/2014F Page 3 of 3 Qasair Rangehoods Installation Instructions...
  • Page 26 Installation must be carried out by the procedure outlined. INSTALLATION INSTRUCTIONS Failure to do so may void the guarantee. Electrical: Wiring to the appliance must comply with State and local Regulations. • WES Connection to be carried out by a registered electrician. •...
  • Page 27 Cool Cool (H =) Maximum Height Nightlight (H =) PowderKote Light Qty Available All-thread Light Centres 300mm 380mm Fixing Centres Filter Qty Corner Type Square Square Condari Pty Ltd. Page 1 of 2 Version: C 30/05/2017F Qasair Rangehoods Installation Instructions...
  • Page 28 (H =) Maximum Height Nightlight (H =) PowderKote Light Qty Available All-thread Light Centres 430mm 480mm 680mm Fixing Centres Filter Qty Corner Type Square Square Square Condari Pty Ltd. Page 2 of 2 Version: C 30/05/2017F Qasair Rangehoods Installation Instructions...
  • Page 29 Cool Cool (H =) Maximum Height Nightlight (H =) PowderKote Light Qty Available All-thread Light Centres 300mm 380mm Fixing Centres Filter Qty Corner Type Square Square Condari Pty Ltd. Page 1 of 2 Version: C 30/05/2017F Qasair Rangehoods Installation Instructions...
  • Page 30 Maximum Height Nightlight (H =) PowderKote Light Qty Available All-thread Light Centres mm x mm 430mm 480mm 680mm Fixing Centres Filter Qty Corner Type Square Square Condari Pty Ltd. Page 2 of 2 Version: C 30/05/2017F Qasair Rangehoods Installation Instructions...
  • Page 31: Wiring Diagram

    ‘Brown-Low’ wires at the same time. This will cause the fan to fail. DRAWING NUMBER REMOTE SWITCH 3 FAN REM SW 3 FAN For further information, please contact Condari Pty Ltd phone: 03 9482 7088 fax: 03 9482 7011 Qasair Rangehoods Installation Instructions www.condari.com.au...
  • Page 32 Be aware that Active voltage must NOT be applied to both the ‘White- High’ or ‘Brown-Low’ wires at the same time. This will cause the fan to fail. For further information, please contact Condari Pty Ltd phone: 03 9482 7088 fax: 03 9482 7011 Qasair Rangehoods Installation Instructions www.condari.com.au...
  • Page 33 Be aware that Active voltage must NOT be applied to both the ‘White- High’ or ‘Brown-Low’ wires at the same time. This will cause the fan to fail. For further information, please contact Condari Pty Ltd phone: 03 9482 7088 fax: 03 9482 7011 Qasair Rangehoods Installation Instructions www.condari.com.au...
  • Page 34 SINGLE MOTOR DUCTING NOTE: This Zinc Alume Strip is provided to join some duct pieces together. It will be clearly shown on the drawing of the piece it is supplied with. I/I: Inside to Inside Measurement 101. DL-1 Single Motor Duct Length 1200mm 101.
  • Page 35 SINGLE MOTOR DUCTING 111. DD-1H R 112. TT-1 113. DLE-DLE Duct Director Single Motor Horizontal Twisted Transition Single Motor Flue Joiner Single Motor Right 114. CD-920 115. CD-920 TO DL-1 116. TR-1 Cavity Duct Extendible Cavity Duct to DL-1 Single Motor Transition DL-1 to 200Ø 117.
  • Page 36 SINGLE MOTOR DUCTING 126. BD/RC-1 CB 127. BD/SQ-RC 200 128. DLE-S/S CAP Back Draft Roof Cowl Single Motor Back Draft Roof Cowl Single Motor 200Ø Stainless Steel Flue Cap to Suit DLE Colourbond 131. WVC-H-1 129. BD/M-1 130. CF 6/7/900H Wall Vent Cover Single Motor Horizontal Back Draft Damper Single Motor Ceiling Flange to Suit 6/7/900H...
  • Page 37 WALL VENT 142. FRC 200 SS 143. FRWV-H-1 SS 141. RC 1 SS Fire Rated 200Ø Roof Cowl Fire Rated Wall Vent Horizontal Roof Cowl Single Motor 445M2 Stainless Steel 445M2 Stainless Steel 445M2 Stainless Steel ROOF COWLS, WALL VENTS AND WALL VENT COVERS All the above ducting pieces are all made in stainless...
  • Page 38 TWIN MOTOR DUCTING NOTE: This Zinc Alume Strip is provided to join some duct pieces together. It will be clearly shown on the drawing of the piece it is supplied with. I/I: Inside to Inside Measurement 201. TMT 202. DL-2 203.
  • Page 39 TWIN MOTOR DUCTING 213. BD-10/12/15-WV-R/R 214. TMT-300 215. TR-2 Back Draft Wall Vent 10/12/1500H Twin Motor Transition to 300Ø Twin Motor Transition from DL-2 to 300Ø 216. DR-300 217. DR-300 CB 218. DR-300/45 Duct Length 300Ø Duct Length 300Ø Colourbond 300Ø...
  • Page 40 TWIN MOTOR DUCTING 229. BD/WV-250 SQ SS 228. BD/WV-250 SQ 230 BD/RC-2 Back Draft Wall 250SQ 445M2 Stainless Back Draft Wall Vent 250SQ Back Draft Roof Cowl Twin Motor Steel 231. BD/RC-2 CB 232. CH-300 233. CH-300 CB Back Draft Roof Cowl Twin Motor Chairman’s Hat 300Ø...
  • Page 41 TWIN MOTOR DUCTING 243.WVC-H-2 SS 245. WVC-V-2 SS 244. WVC-V-2 Wall Vent Cover Twin Motor Horizontal Wall Vent Cover Twin Motor Vertical Wall Vent Cover Twin Motor Vertical 445M2 Stainless Steel 445M2 Stainless Steel 247. WVC-250 SQ SS 246. WVC-250 SQ 248.
  • Page 42 TWIN MOTOR DUCTING 260. RV 300 SS 258. CF 3F-1500-2 259. RCP 300 SS Roof Ventilation Cowl 300Ø 445M2 Roof Cap 300Ø 445M2 Stainless Steel Ceiling Flange to Suit 3F 1500-2 Stainless Steel 262. RC 2 SS 263. FRC 300 SS 261.
  • Page 43 TRIPLE MOTOR DUCTING NOTE: This Zinc Alume Strip is provided to join some duct pieces together. It will be clearly shown on the drawing of the piece it is supplied with. I/I: Inside to Inside Measurement 301. 3MT-DL-3 302. DL-3 303.
  • Page 44 TRIPLE MOTOR DUCTING 315. BD/RC-3 SS 313. DR-350/90 314. BD/RC-3 Back Draft Roof Cowl Triple Motor 350Ø Bend 90º Back Draft Roof Cowl Triple Motor 445M2 Stainless Steel 317. BD/SQ-RC 350 SS 316. BD/SQ-RC 350 318. CH-350 Back Draft Roof Cowl 350Ø Back Draft Roof Cowl Triple Motor 350SQ Chairmans Hat 350Ø...
  • Page 45 TRIPLE MOTOR DUCTING 328. DD-3V-L 329. DD-3V-R 330. BD/WV-350Ø Duct Director Triple Motor Vertical Left Duct Director Triple Motor Vertical Right Back Draft Wall Vent WALL VENT WALL VENT 331. FRWV-H-3 SS 333. FRC 350 SS 332. FRWV-V-3 SS Fire Rated Wall Vent Triple Motor Fire Rated Roof Cowl 350Ø...
  • Page 46: Installation Ideas

    INSTALLATION IDEAS Condari recommends Qasair and Condor Rangehoods be installed using ducting that is: • rigid • non-flammable • correctly sized to ensure maximum air movement and minimum noise levels. Ducting incorrectly with flexible or smaller diameter ducting will dramatically reduce the air movement and increase the noise level of the rangehood and will void the manufacturer’s warranty.
  • Page 47 FA 90L-2 T FA 90L-2 T Rangehood Rangehood 7. FA 90L-2 T 8. FA 90L-2 T FA 90L-2 B Rangehood FA 90L-2 T Rangehood 9. FA 90L-2 T 10. FA 90L-2 B FA 90L-2 T FA 90L-2 T Rangehood Rangehood 11.
  • Page 48 600HL-1 T / 700HL-1 T / 900HL-1 T Rangehood 600HL-1 T Rangehood 13. 600HL-1 T / 700HL-1 T / 900HL-1 T 14. 600HL-1 T CON 60L-1 T Rangehood CON 80L-1 T Rangehood 15. CON 60L-1 T 16. CON 80L-1 T CON 60L-1 T Rangehood CON 80L-2 T Rangehood 17.
  • Page 49 1200HL-2 T Rangehood LIS 800L-2 T Rangehood 19. 1200HL-2 T 20. LIS 800L-2 T LIS 1000L-2 T 3F 900L-2 T / 1200L-2 T Rangehood Rangehood 21. LIS 1000L-2 T 22. 3F 900L-2 T / 1200L-2 T LIS 800L-1 T LIS 500L-1 T Rangehood Rangehood 23.
  • Page 50 LIS 1200L-2 B Rangehood LIS 1000L-2 T CON 80L-1 T Rangehood Rangehood 25. CON 80L-1 T / LIS 1000-2 T 26. LIS 1200L-2 B FA-60L-1 B Rangehood FA-90L-1 T Rangehood 2. FA 90L-1 T 1. FA 60L-1 B Qasair Rangehoods Installation Instructions...
  • Page 51: Filter Cleaning

    Ensure the filters are completely dry before placing them back. Do not operate the rangehood without the filters installed. Condari does not recommend the use of corrosive, caustic or acidic products, particulary industrial or citric products. Condari has experienced problems with many of the dishwashing detergents now on the market.
  • Page 52 No other person, or firm or corporation is authorised by Condari to offer or give on its behalf any other greater warranty than that given by Condari under this warranty.
  • Page 53 These brands have a mega joule rating of up to 95 mj and therefore special hoods are required for the appliances. CONDARI will manufacture special rangehoods to go over commercial cooking appliances situated in domestic kitchens. Once the heat output is over 50 mega joule a special rangehood is required.
  • Page 54 Tel: +61 3 9482 7088 Fax: +61 3 9482 7011 Email: sales@condari.com.au Pleae Note that the Warranty is from the date of installation and the service technician will need to see proof of purchase so he can provide service under the guarantee.
  • Page 55 EXTENDED WARRANTY Condari Pty Ltd provides an extended warranty from 36 months to 72 months if installed by an authorised Qasair installer and the below form is completed. The authorised installer also offers a warranty on their workmanship for the same period of 72 months with a guarantee that the installation is in compliance with ‘Qasair installation instructions’.
  • Page 56 NOTES Qasair Rangehoods Installation Instructions...
  • Page 57 NOTES Qasair Rangehoods Installation Instructions...
  • Page 58 NOTES Qasair Rangehoods Installation Instructions...
  • Page 59 NOTES Qasair Rangehoods Installation Instructions...
  • Page 60 N e w Z e a l a n d Kouzina Appliances Email: sales@kouzina.co.nz S i n g a p o r e Eldric Marketing Pte Ltd Email: enquiry@eldric.sg CONDARI RESERVES THE RIGHT TO CHANGE SPECIFICATION WITHOUT NOTICE QASAIR RANGEHOODS MADE IN RINGWOOD 3134 rev. 150318 www.condari.com.au...

Table of Contents