Important Information Instructions for Models H Series & PYR Instructions for Models 3F / SEA / SMF / CM / STA / STF / IN Instructions for Models BRH / LAM / BAR / MAR / MAJ / FAS Remote Switching Specifications Ducting Pieces Installation Ideas Operation Details, Rangehood Cleaning, Filter Cleaning...
Do not reduce the duct size or have sharp bends. Enlarge the duct size if the duct is to run 6 metres or longer. Advice from CONDARI is available to ensure optimum performance.
Page 5
5. NOTE: CONDARI recommend an air movement of between 1000 to 1400 cubic metres per hour over an indoor barbecue, depending on the length of the duct run. Ensure a twin motor unit is installed over indoor barbecues for optimum results.
Page 6
INSTALLATION INSTRUCTIONS • H SERIES • PYR Installation must be carried out by the procedure outlined. Failure to do so may void the guarantee. Electrical: Wiring to the appliance must comply with State and local Regulations. Connection to be carried out by a registered electrician. Recommended fixing points MOUNTING BRACKET •...
Page 7
Nightlight Power Entry Horizontal 125mm 135mm 210mm PowderKote Light Qty Available Light Centres 310mm 310mm 510mm Outlet Spacing Filter Qty Corner Type Square Square Square Condari Pty Ltd. Page 1 of 2 Version: C 20/01/2015F Qasair Rangehoods Installation Instructions...
Page 8
Power Entry Horizontal 150mm 250mm 375mm PowderKote Light Qty Available Light Centres 510mm 648mm 816mm Outlet Spacing 75mm 100mm 100mm Filter Qty Corner Type Square Square Square Condari Pty Ltd. Page 2 of 2 Version: C 20/01/2015F Qasair Rangehoods Installation Instructions...
Page 9
LED Light Cool (H =) Maximum Height Nightlight (H =) PowderKote Light Qty Available All-thread Light Centres 510mm Fixing Centres Filter Qty Square Corner Type Condari Pty Ltd. Page 1 of 1 Version: B 20/01/2015F Qasair Rangehoods Installation Instructions...
Page 10
INSTALLATION INSTRUCTIONS • 3F • SEA • SMF • CM • STA / STF • IN (REMOTE SWITCHED) Installation must be carried out by the procedure outlined. Failure to do so may void the guarantee. Electrical: Wiring to the appliance must comply with State and local Regulations. Connection to be carried out by a registered electrician.
Page 11
(H =) Maximum Height Nightlight 1680mm 1680mm (H =) PowderKote Light Qty Available All-thread Light Centres 510mm 648mm Fixing Centres Filter Qty Corner Type Round Round Condari Pty Ltd. Page 1 of 2 Version: C 20/01/2015F Qasair Rangehoods Installation Instructions...
Page 12
(H =) Maximum Height Nightlight 1680mm 1680mm (H =) PowderKote Light Qty Available All-thread Light Centres 648mm 816mm Fixing Centres Filter Qty Corner Type Round Round Condari Pty Ltd. Version: C 20/01/2015F Page 2 of 2 Qasair Rangehoods Installation Instructions...
Page 13
1450mm (H =) PowderKote Light Qty Available All-thread Light Centres Centre 510mm 510mm 400mm 700mm 700mm Fixing Centres Filter Qty Corner Type Square Square Square Condari Pty Ltd. Page 1 of 2 Version: C 20/01/2015F Qasair Rangehoods Installation Instructions...
Page 15
(H =) PowderKote Light Qty Available 3 1 0 m m All-thread Light Centres 510mm 510mm Fixing Centres Filter Qty Corner Type Round Round Round Condari Pty Ltd. Page 1 of 4 Version: C 20/01/2015F Qasair Rangehoods Installation Instructions...
Page 16
Cool (H =) Maximum Height Nightlight (H =) PowderKote Light Qty Available All-thread Light Centres 510mm 648mm Fixing Centres Filter Qty Corner Type Round Round Condari Pty Ltd. Page 2 of 4 Version: C 20/01/2015F Qasair Rangehoods Installation Instructions...
Page 17
(H =) Maximum Height Nightlight (H =) PowderKote Light Qty Available All-thread Light Centres 816mm 816mm 422mm Fixing Centres Filter Qty Corner Type Round Round Round Condari Pty Ltd. Page 3 of 4 Version: C 20/01/2015F Qasair Rangehoods Installation Instructions...
Page 18
300mm (H =) Maximum Height 1450mm 1450mm 1450mm 1450mm 1450mm 1450mm 1450mm 1450mm (H =) Powderkote A v a i l a b l e Condari Pty Ltd. Version: C 20/01/2015F Page 4 of 4 Qasair Rangehoods Installation Instructions...
Page 19
Cool (H =) Maximum Height Nightlight (H =) PowderKote Light Qty Available All-thread Light Centres 510mm 510mm Fixing Centres Filter Qty Corner Type Round Round Condari Pty Ltd. Page 1 of 3 Version: C 20/01/2015F Qasair Rangehoods Installation Instructions...
Page 20
Cool (H =) Maximum Height Nightlight (H =) PowderKote Light Qty Available All-thread Light Centres 510mm 648mm Fixing Centres Filter Qty Corner Type Round Round Condari Pty Ltd. Version: C 20/01/2015F Page 2 of 3 Qasair Rangehoods Installation Instructions...
Page 21
3 5 m m Minimum Height 335mm 335mm (H =) Maximum Height 1450mm 1450mm 1450mm 1450mm (H =) Powderkote A v a i l a b l e Condari Pty Ltd. Version: C 20/01/2015F Page 3 of 3 Qasair Rangehoods Installation Instructions...
Page 22
Cool 415mm (H =) Maximum Height Nightlight 1550mm (H =) PowderKote Light Qty Available All-thread Light Centres 510mm Fixing Centres Filter Qty Corner Type Round Condari Pty Ltd. Page 1 of 3 Version: E 29/06/2016F Qasair Rangehoods Installation Instructions...
Page 23
Cool 740mm (H =) Maximum Height Nightlight 1550mm (H =) PowderKote Light Qty Available All-thread Light Centres 510mm Fixing Centres Filter Qty Corner Type Round Condari Pty Ltd. Page 2 of 3 Version: E 29/06/2016F Qasair Rangehoods Installation Instructions...
Page 24
Cool 740mm (H =) Maximum Height Nightlight 1550mm (H =) PowderKote Light Qty Available All-thread Light Centres 648mm Fixing Centres Filter Qty Corner Type Round Condari Pty Ltd. Page 3 of 3 Version: E 29/06/2016F Qasair Rangehoods Installation Instructions...
Page 25
(H =) Maximum Height Nightlight 1280mm 1280mm (H =) PowderKote Light Qty Available All-thread Light Centres 510mm 648mm Fixing Centres Filter Qty Corner Type Square Square Condari Pty Ltd. Page 1 of 1 Version: C 20/01/2015F Qasair Rangehoods Installation Instructions...
Page 26
Cool (H =) Maximum Height Nightlight (H =) PowderKote Light Qty Available All-thread Light Centres Centre 285mm Fixing Centres Filter Qty Corner Type Square Square Condari Pty Ltd. Page 1 of 2 Version: A 28/11/2014F Qasair Rangehoods Installation Instructions...
Page 27
Cool (H =) Maximum Height Nightlight (H =) PowderKote Light Qty Available All-thread Light Centres 560mm 560mm Fixing Centres Filter Qty Corner Type Square Square Condari Pty Ltd. Page 2 of 2 Version: A 28/11/2014F Qasair Rangehoods Installation Instructions...
Page 28
Installation must be carried out by the procedure outlined. INSTALLATION INSTRUCTIONS Failure to do so may void the guarantee. Electrical: Wiring to the appliance must comply with State and local Regulations. • BRH / LAM Connection to be carried out by a registered electrician. •...
‘Brown-Low’ wires at the same time. This will cause the fan to fail. DRAWING NUMBER REMOTE SWITCH 3 FAN REM SW 3 FAN For further information, please contact Condari Pty Ltd phone: 03 9482 7088 fax: 03 9482 7011 Qasair Rangehoods Installation Instructions www.condari.com.au...
Page 40
Be aware that Active voltage must NOT be applied to both the ‘White- High’ or ‘Brown-Low’ wires at the same time. This will cause the fan to fail. For further information, please contact Condari Pty Ltd phone: 03 9482 7088 fax: 03 9482 7011 Qasair Rangehoods Installation Instructions www.condari.com.au...
Page 41
Be aware that Active voltage must NOT be applied to both the ‘White- High’ or ‘Brown-Low’ wires at the same time. This will cause the fan to fail. For further information, please contact Condari Pty Ltd phone: 03 9482 7088 fax: 03 9482 7011 Qasair Rangehoods Installation Instructions www.condari.com.au...
Page 42
SINGLE MOTOR DUCTING NOTE: This Zinc Alume Strip is provided to join some duct pieces together. It will be clearly shown on the drawing of the piece it is supplied with. I/I: Inside to Inside Measurement 101. DL-1 Single Motor Duct Length 1200mm 101.
Page 43
SINGLE MOTOR DUCTING 111. DD-1H R 112. TT-1 113. DLE-DLE Duct Director Single Motor Horizontal Twisted Transition Single Motor Flue Joiner Single Motor Right 114. CD-920 115. CD-920 TO DL-1 116. TR-1 Cavity Duct Extendible Cavity Duct to DL-1 Single Motor Transition DL-1 to 200Ø 117.
Page 44
SINGLE MOTOR DUCTING 126. BD/RC-1 CB 127. BD/SQ-RC 200 128. DLE-S/S CAP Back Draft Roof Cowl Single Motor Back Draft Roof Cowl Single Motor 200Ø Stainless Steel Flue Cap to Suit DLE Colourbond 131. WVC-H-1 129. BD/M-1 130. CF 6/7/900H Wall Vent Cover Single Motor Horizontal Back Draft Damper Single Motor Ceiling Flange to Suit 6/7/900H...
WALL VENT 142. FRC 200 SS 143. FRWV-H-1 SS 141. RC 1 SS Fire Rated 200Ø Roof Cowl Fire Rated Wall Vent Horizontal Roof Cowl Single Motor 445M2 Stainless Steel 445M2 Stainless Steel 445M2 Stainless Steel ROOF COWLS, WALL VENTS AND WALL VENT COVERS All the above ducting pieces are all made in stainless...
Page 46
TWIN MOTOR DUCTING NOTE: This Zinc Alume Strip is provided to join some duct pieces together. It will be clearly shown on the drawing of the piece it is supplied with. I/I: Inside to Inside Measurement 201. TMT 202. DL-2 203.
Page 47
TWIN MOTOR DUCTING 213. BD-10/12/15-WV-R/R 214. TMT-300 215. TR-2 Back Draft Wall Vent 10/12/1500H Twin Motor Transition to 300Ø Twin Motor Transition from DL-2 to 300Ø 216. DR-300 217. DR-300 CB 218. DR-300/45 Duct Length 300Ø Duct Length 300Ø Colourbond 300Ø...
Page 48
TWIN MOTOR DUCTING 229. BD/WV-250 SQ SS 228. BD/WV-250 SQ 230 BD/RC-2 Back Draft Wall 250SQ 445M2 Stainless Back Draft Wall Vent 250SQ Back Draft Roof Cowl Twin Motor Steel 231. BD/RC-2 CB 232. CH-300 233. CH-300 CB Back Draft Roof Cowl Twin Motor Chairman’s Hat 300Ø...
Page 49
TWIN MOTOR DUCTING 243.WVC-H-2 SS 245. WVC-V-2 SS 244. WVC-V-2 Wall Vent Cover Twin Motor Horizontal Wall Vent Cover Twin Motor Vertical Wall Vent Cover Twin Motor Vertical 445M2 Stainless Steel 445M2 Stainless Steel 247. WVC-250 SQ SS 246. WVC-250 SQ 248.
Page 50
TWIN MOTOR DUCTING 260. RV 300 SS 258. CF 3F-1500-2 259. RCP 300 SS Roof Ventilation Cowl 300Ø 445M2 Roof Cap 300Ø 445M2 Stainless Steel Ceiling Flange to Suit 3F 1500-2 Stainless Steel 262. RC 2 SS 263. FRC 300 SS 261.
Page 51
TRIPLE MOTOR DUCTING NOTE: This Zinc Alume Strip is provided to join some duct pieces together. It will be clearly shown on the drawing of the piece it is supplied with. I/I: Inside to Inside Measurement 301. 3MT-DL-3 302. DL-3 303.
Page 52
TRIPLE MOTOR DUCTING 315. BD/RC-3 SS 313. DR-350/90 314. BD/RC-3 Back Draft Roof Cowl Triple Motor 350Ø Bend 90º Back Draft Roof Cowl Triple Motor 445M2 Stainless Steel 317. BD/SQ-RC 350 SS 316. BD/SQ-RC 350 318. CH-350 Back Draft Roof Cowl 350Ø Back Draft Roof Cowl Triple Motor 350SQ Chairmans Hat 350Ø...
Page 53
TRIPLE MOTOR DUCTING 328. DD-3V-L 329. DD-3V-R 330. BD/WV-350Ø Duct Director Triple Motor Vertical Left Duct Director Triple Motor Vertical Right Back Draft Wall Vent WALL VENT WALL VENT 331. FRWV-H-3 SS 333. FRC 350 SS 332. FRWV-V-3 SS Fire Rated Wall Vent Triple Motor Fire Rated Roof Cowl 350Ø...
INSTALLATION IDEAS Condari recommends Qasair and Condor Rangehoods be installed using ducting that is: • rigid • non-flammable • correctly sized to ensure maximum air movement and minimum noise levels. Ducting incorrectly with flexible or smaller diameter ducting will dramatically reduce the air movement and increase the noise level of the rangehood and will void the manufacturer’s warranty.
Page 55
FA 90L-2 T FA 90L-2 T Rangehood Rangehood 7. FA 90L-2 T 8. FA 90L-2 T FA 90L-2 B Rangehood FA 90L-2 T Rangehood 9. FA 90L-2 T 10. FA 90L-2 B FA 90L-2 T FA 90L-2 T Rangehood Rangehood 11.
Page 56
600HL-1 T / 700HL-1 T / 900HL-1 T Rangehood 600HL-1 T Rangehood 13. 600HL-1 T / 700HL-1 T / 900HL-1 T 14. 600HL-1 T CON 60L-1 T Rangehood CON 80L-1 T Rangehood 15. CON 60L-1 T 16. CON 80L-1 T CON 60L-1 T Rangehood CON 80L-2 T Rangehood 17.
Page 57
1200HL-2 T Rangehood LIS 800L-2 T Rangehood 19. 1200HL-2 T 20. LIS 800L-2 T LIS 1000L-2 T 3F 900L-2 T / 1200L-2 T Rangehood Rangehood 21. LIS 1000L-2 T 22. 3F 900L-2 T / 1200L-2 T LIS 800L-1 T LIS 500L-1 T Rangehood Rangehood 23.
Page 58
LIS 1200L-2 B Rangehood LIS 1000L-2 T CON 80L-1 T Rangehood Rangehood 25. CON 80L-1 T / LIS 1000-2 T 26. LIS 1200L-2 B FA-60L-1 B Rangehood FA-90L-1 T Rangehood 2. FA 90L-1 T 1. FA 60L-1 B Qasair Rangehoods Installation Instructions...
Page 59
Ensure the filters are completely dry before placing them back. Do not operate the rangehood without the filters installed. Condari does not recommend the use of corrosive, caustic or acidic products, particulary industrial or citric products. Condari has experienced problems with many of the dishwashing detergents now on the market.
No other person, or firm or corporation is authorised by Condari to offer or give on its behalf any other greater warranty than that given by Condari under this warranty.
Page 61
These brands have a mega joule rating of up to 95 mj and therefore special hoods are required for the appliances. CONDARI will manufacture special rangehoods to go over commercial cooking appliances situated in domestic kitchens. Once the heat output is over 50 mega joule a special rangehood is required.
Page 62
Tel: +61 3 9482 7088 Fax: +61 3 9482 7011 Email: sales@condari.com.au Pleae Note that the Warranty is from the date of installation and the service technician will need to see proof of purchase so he can provide service under the guarantee.
Page 63
EXTENDED WARRANTY Condari Pty Ltd provides an extended warranty from 36 months to 72 months if installed by an authorised Qasair installer and the below form is completed. The authorised installer also offers a warranty on their workmanship for the same period of 72 months with a guarantee that the installation is in compliance with ‘Qasair installation instructions’.
Page 68
N e w Z e a l a n d Kouzina Appliances Email: sales@kouzina.co.nz S i n g a p o r e Eldric Marketing Pte Ltd Email: enquiry@eldric.sg CONDARI RESERVES THE RIGHT TO CHANGE SPECIFICATION WITHOUT NOTICE QASAIR RANGEHOODS MADE IN RINGWOOD 3134 rev. 150318 www.condari.com.au...
Need help?
Do you have a question about the QASAIR SEA and is the answer not in the manual?
Questions and answers